Orbital blow-out fractures reconstruction aims to restore the continuity of the orbital floor, to provide support of orbital contents and prevent soft tissues' fibrosis. Different materials have been tested over the years to reach this purpose. Traditionally, autogenous grafts have been used as the material of choice; in recent years alloplastic materials have gained popularity because of their availability and ease of use. The purpose of this study was to review materials used in orbital floor reconstructive surgery at the Department of Maxillo-Facial Surgery of University of Rome '' La Sapienza '', with emphasis on their biocompatibility, their shaping features, and mechanical properties. This report presents the results obtained by the application of these products on 379 patients who underwent surgical treatment for blow-out fractures from 1995 to 2003: the diagnosis of fracture of the orbital floor was based on clinical symptoms and CT axial scanning through coronal reconstruction. Followup period spanned from 1 to 8 years.

Orbital floor restoration / Claudio, Rinna; Ungari, Claudio; Andrea, Saltarel; Cassoni, Andrea; Gabriele, Reale. - In: THE JOURNAL OF CRANIOFACIAL SURGERY. - ISSN 1049-2275. - 16:6(2005), pp. 968-972. [10.1097/01.scs.0000186308.16795.8b]

Orbital floor restoration

UNGARI, Claudio;CASSONI, ANDREA;
2005

Abstract

Orbital blow-out fractures reconstruction aims to restore the continuity of the orbital floor, to provide support of orbital contents and prevent soft tissues' fibrosis. Different materials have been tested over the years to reach this purpose. Traditionally, autogenous grafts have been used as the material of choice; in recent years alloplastic materials have gained popularity because of their availability and ease of use. The purpose of this study was to review materials used in orbital floor reconstructive surgery at the Department of Maxillo-Facial Surgery of University of Rome '' La Sapienza '', with emphasis on their biocompatibility, their shaping features, and mechanical properties. This report presents the results obtained by the application of these products on 379 patients who underwent surgical treatment for blow-out fractures from 1995 to 2003: the diagnosis of fracture of the orbital floor was based on clinical symptoms and CT axial scanning through coronal reconstruction. Followup period spanned from 1 to 8 years.
2005
blow-out fracture; orbital floor reconstruction; orbital implant
01 Pubblicazione su rivista::01a Articolo in rivista
Orbital floor restoration / Claudio, Rinna; Ungari, Claudio; Andrea, Saltarel; Cassoni, Andrea; Gabriele, Reale. - In: THE JOURNAL OF CRANIOFACIAL SURGERY. - ISSN 1049-2275. - 16:6(2005), pp. 968-972. [10.1097/01.scs.0000186308.16795.8b]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/121516
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 63
  • ???jsp.display-item.citation.isi??? 61
social impact