In this paper, we present a surface-plasmon-resonance-based immunosensor for the real-time detection of cortisol and cortisone levels in urine and saliva samples. The method proposed here is simple, rapid, economic, sensitive, robust, and reproducible thanks also to the special features of the polycarboxylate-hydrogel-based coatings used for the antibody immobilization. The sensor surface displays a high level of stability during repeated regeneration and affinity reaction cycles. The immunosensor shows high specificity for cortisol and cortisone; furthermore, no significant interferences from other steroids with a similar chemical structure have been observed. The suitability of the hydrogel coating for the prevention of nonspecific binding is also investigated. A good correlation is noticed between the results obtained by the proposed method and the reference liquid chromatography/tandem mass spectrometry method for the analysis of cortisol and cortisone in urine and saliva samples. Standard curves for the detection of cortisol and cortisone in saliva and urine are characterized by a detection limit less than 10 mu g l(-1), sufficiently sensitive for both clinical and forensic use.

Surface plasmon resonance immunosensor for cortisol and cortisone determination / Frasconi, Marco; Monica, Mazzarino; Botre', Francesco; Mazzei, Franco. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - STAMPA. - 394:8(2009), pp. 2151-2159. [10.1007/s00216-009-2914-6]

Surface plasmon resonance immunosensor for cortisol and cortisone determination

FRASCONI, Marco;BOTRE', Francesco;MAZZEI, Franco
2009

Abstract

In this paper, we present a surface-plasmon-resonance-based immunosensor for the real-time detection of cortisol and cortisone levels in urine and saliva samples. The method proposed here is simple, rapid, economic, sensitive, robust, and reproducible thanks also to the special features of the polycarboxylate-hydrogel-based coatings used for the antibody immobilization. The sensor surface displays a high level of stability during repeated regeneration and affinity reaction cycles. The immunosensor shows high specificity for cortisol and cortisone; furthermore, no significant interferences from other steroids with a similar chemical structure have been observed. The suitability of the hydrogel coating for the prevention of nonspecific binding is also investigated. A good correlation is noticed between the results obtained by the proposed method and the reference liquid chromatography/tandem mass spectrometry method for the analysis of cortisol and cortisone in urine and saliva samples. Standard curves for the detection of cortisol and cortisone in saliva and urine are characterized by a detection limit less than 10 mu g l(-1), sufficiently sensitive for both clinical and forensic use.
2009
antidoping; cortisol; cortisol - cortisone - spr - immunosensor - antidoping; cortisone; immunosensor; spr
01 Pubblicazione su rivista::01a Articolo in rivista
Surface plasmon resonance immunosensor for cortisol and cortisone determination / Frasconi, Marco; Monica, Mazzarino; Botre', Francesco; Mazzei, Franco. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - STAMPA. - 394:8(2009), pp. 2151-2159. [10.1007/s00216-009-2914-6]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/120729
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 20
  • Scopus 61
  • ???jsp.display-item.citation.isi??? 53
social impact