The Belle II VerteX Detector (VXD) is a 6 layers silicon tracker device that will cope with an unprecedented luminosity of 8×1035 cm−2s−1 achievable by the new SuperKEKB e+e − collider, at the KEK laboratory (Tsukuba, Japan). All environment parameters such as temperature, humidity and radiation levels, must be constantly monitored and under certain conditions action must be promptly taken, such as interlocking the power supply or delivering an abort signal to the SuperKEKB collider. In this contribution we describe the Belle II VXD monitoring system. We also present the first results of the temperature and humidity system commissioned in a Beam Test at DESY in April 2016 and the preliminary results of the radiation monitoring achieved with a prototype system during the first SuperKEKB commissioning phase at KEK in February-June 2016.

The Monitoring System of the Belle II Vertex Detector / Vitale, Lorenzo; Adamczyk, K.; Aihara, H.; Angelini, C.; Aziz, T.; Babu, V.; Bacher, S.; Bahinipati, S.; Barberio, E.; Baroncelli, Ti.; Baroncelli, To.; Basith, A. K; Batignani, G.; Bauer, A.; Behera, P. K.; Bergauer, T.; Bettarini, S.; Bhuyan, B.; Bilka, T.; Bosi, F.; Bosisio, L.; Bozek, A.; Buchsteiner, F.; Bulla, L.; Caria, G.; Casarosa, G.; Cotter, G.; Ceccanti, M.; Cervenkov, D.; Chendvankar, S. R; Dash, N.; Divekar, S. T; Doležal, Z.; Dutta, D.; Forti, F.; Friedl, M.; Giuressi, D.; Hara, K.; Higuchi, T.; Horiguchi, T.; Irmler, C.; Ishikawa, A.; Jeon, H. B.; Joo, C.; Kandra, J.; Kambara, N.; Kang, K. H; Kawasaki, T.; Kodyš, P.; Kohriki, T.; Koike, S.; Kolwalkar, M. M; Kumar, R.; Kun, W.; Kvasnicka, P.; Lanceri, L.; Lettenbicher, J.; Libby, J.; Lueck, T.; Maki, M.; Mammini, P.; Mayekar, S. N; Mohanty, G. B; Mohanty, S.; Morii, T.; Nakamura, K. R; Natkaniec, Z.; Onuki, Y.; Ostrowicz, W.; Paladino, A.; Paoloni, E.; Park, H.; Pilo, F.; Profeti, A.; Rashevskaya, I.; Rizzo, G.; Resmi, P. K; Rozanska, M.; Sasaki, J.; Sato, N.; Schultschik, S.; Schwanda, C.; Seino, Y.; Shimizu, N.; Stypula, J.; Suzuki, J.; Tanaka, S.; Taylor, G. N; Thalmeier, R.; Thomas, R.; Tsuboyama, T.; Uozumi, S.; Urquijo, P.; Watanuki, S.; Watanabe, M.; Watson, I. J; Webb, J.; Wiechczynski, J.; Williams, S.; Würkner, B.; Yamamoto, H.; Yin, H.; Yoshinobu, T.; Zani, L.; Pietro, G. D; Pietro, G. De. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - (2017), p. 051. [10.22323/1.287.0051]

The Monitoring System of the Belle II Vertex Detector

Forti, F.;Lanceri, L.;Paladino, A.;
2017

Abstract

The Belle II VerteX Detector (VXD) is a 6 layers silicon tracker device that will cope with an unprecedented luminosity of 8×1035 cm−2s−1 achievable by the new SuperKEKB e+e − collider, at the KEK laboratory (Tsukuba, Japan). All environment parameters such as temperature, humidity and radiation levels, must be constantly monitored and under certain conditions action must be promptly taken, such as interlocking the power supply or delivering an abort signal to the SuperKEKB collider. In this contribution we describe the Belle II VXD monitoring system. We also present the first results of the temperature and humidity system commissioned in a Beam Test at DESY in April 2016 and the preliminary results of the radiation monitoring achieved with a prototype system during the first SuperKEKB commissioning phase at KEK in February-June 2016.
2017
belle ii; silicon detector; vertex detector; silicon vertex detector
01 Pubblicazione su rivista::01a Articolo in rivista
The Monitoring System of the Belle II Vertex Detector / Vitale, Lorenzo; Adamczyk, K.; Aihara, H.; Angelini, C.; Aziz, T.; Babu, V.; Bacher, S.; Bahinipati, S.; Barberio, E.; Baroncelli, Ti.; Baroncelli, To.; Basith, A. K; Batignani, G.; Bauer, A.; Behera, P. K.; Bergauer, T.; Bettarini, S.; Bhuyan, B.; Bilka, T.; Bosi, F.; Bosisio, L.; Bozek, A.; Buchsteiner, F.; Bulla, L.; Caria, G.; Casarosa, G.; Cotter, G.; Ceccanti, M.; Cervenkov, D.; Chendvankar, S. R; Dash, N.; Divekar, S. T; Doležal, Z.; Dutta, D.; Forti, F.; Friedl, M.; Giuressi, D.; Hara, K.; Higuchi, T.; Horiguchi, T.; Irmler, C.; Ishikawa, A.; Jeon, H. B.; Joo, C.; Kandra, J.; Kambara, N.; Kang, K. H; Kawasaki, T.; Kodyš, P.; Kohriki, T.; Koike, S.; Kolwalkar, M. M; Kumar, R.; Kun, W.; Kvasnicka, P.; Lanceri, L.; Lettenbicher, J.; Libby, J.; Lueck, T.; Maki, M.; Mammini, P.; Mayekar, S. N; Mohanty, G. B; Mohanty, S.; Morii, T.; Nakamura, K. R; Natkaniec, Z.; Onuki, Y.; Ostrowicz, W.; Paladino, A.; Paoloni, E.; Park, H.; Pilo, F.; Profeti, A.; Rashevskaya, I.; Rizzo, G.; Resmi, P. K; Rozanska, M.; Sasaki, J.; Sato, N.; Schultschik, S.; Schwanda, C.; Seino, Y.; Shimizu, N.; Stypula, J.; Suzuki, J.; Tanaka, S.; Taylor, G. N; Thalmeier, R.; Thomas, R.; Tsuboyama, T.; Uozumi, S.; Urquijo, P.; Watanuki, S.; Watanabe, M.; Watson, I. J; Webb, J.; Wiechczynski, J.; Williams, S.; Würkner, B.; Yamamoto, H.; Yin, H.; Yoshinobu, T.; Zani, L.; Pietro, G. D; Pietro, G. De. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - (2017), p. 051. [10.22323/1.287.0051]
File allegati a questo prodotto
File Dimensione Formato  
Vitale_The Monitoring System_2017.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.37 MB
Formato Adobe PDF
2.37 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1200379
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact