The High Luminosity Large Hadron Collider (HL-LHC) project at CERN calls for increasing beam intensity in the injector chain. In the Proton Synchrotron (PS), a pre-injector of the LHC, these intensities can result in beam instabilities and potential RF heating of machine components, such that impedance mitigation measures are required. To study these intensity effects, the PS impedance model has been developed and is continuously updated. Each new machine element that is to be added into the accelerator requires an impedance study to minimize its contribution with respect to the machine's overall impedance budget. In such a context, this paper presents the impedance analysis of the new design of the internal beam dump for the PS, showing the design process required to reduce the impedance contribution of this element. Furthermore, the impedance analysis of the currently installed beam dump is analysed in order to compare the impedance contributions of the two designs.
Impedance analysis of new PS internal dump design / Popovic, Branko; Teofili, Lorenzo; Vollinger, Christine. - (2018), pp. 3083-3086. (Intervento presentato al convegno 9th International Particle Accelerator Conference tenutosi a Vancouver, Canada) [10.18429/jacow-ipac2018-thpaf052].
Impedance analysis of new PS internal dump design
Lorenzo Teofili;
2018
Abstract
The High Luminosity Large Hadron Collider (HL-LHC) project at CERN calls for increasing beam intensity in the injector chain. In the Proton Synchrotron (PS), a pre-injector of the LHC, these intensities can result in beam instabilities and potential RF heating of machine components, such that impedance mitigation measures are required. To study these intensity effects, the PS impedance model has been developed and is continuously updated. Each new machine element that is to be added into the accelerator requires an impedance study to minimize its contribution with respect to the machine's overall impedance budget. In such a context, this paper presents the impedance analysis of the new design of the internal beam dump for the PS, showing the design process required to reduce the impedance contribution of this element. Furthermore, the impedance analysis of the currently installed beam dump is analysed in order to compare the impedance contributions of the two designs.File | Dimensione | Formato | |
---|---|---|---|
Popovic_Impedance_2018.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
855.43 kB
Formato
Adobe PDF
|
855.43 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.