The Extreme Light Infrastructure - Nuclear Physics Gamma Beam System (ELI-NP GBS) will be installed and commissioned starting within the next year in Magurele, Romania. It will generate gamma beam through Compton back-scattering of a recirculated laser and a multi-bunch electron beam, produced by a 720 MeV LINAC. In order to obtain bunch by bunch position measurements, four cavity beam position monitors (cBPM) near the two interaction points are foreseen. Extensive tests on the cBPM readout electronics, recently developed by Instrumentation Technologies and acquired for ELI-NP GBS, were performed in laboratory at INFN-LNF and at FLASH in DESY, during the user operation. In the latter case, three cBPMs installed along the LINAC, with similar features as the ones of ELI-NP GBS, were used as measuring devices and signal sources for the read-out electronics under test. We present here the measurements collected and the related analysis, with a particular focus on the beam position measurement resolution.
Measurements with the ELI-NP cavity Beam Position Monitor Read-out Electronics at FLASH / Franzini, Giovanni; Baricevic, Borut; Cargnelutti, Manuel; Lipka, Dirk; Marongiu, Marco; Mostacci, Andrea; Pellegrini, Donato; Serio, Mario; Stella, Angelo; Variola, Alessandro. - (2018). (Intervento presentato al convegno International Particle Accelerator Conference 2018 tenutosi a Vancouver, Canada) [10.18429/jacow-ipac2018-wepal012].
Measurements with the ELI-NP cavity Beam Position Monitor Read-out Electronics at FLASH
Giovanni Franzini;Marco Marongiu;Andrea Mostacci;
2018
Abstract
The Extreme Light Infrastructure - Nuclear Physics Gamma Beam System (ELI-NP GBS) will be installed and commissioned starting within the next year in Magurele, Romania. It will generate gamma beam through Compton back-scattering of a recirculated laser and a multi-bunch electron beam, produced by a 720 MeV LINAC. In order to obtain bunch by bunch position measurements, four cavity beam position monitors (cBPM) near the two interaction points are foreseen. Extensive tests on the cBPM readout electronics, recently developed by Instrumentation Technologies and acquired for ELI-NP GBS, were performed in laboratory at INFN-LNF and at FLASH in DESY, during the user operation. In the latter case, three cBPMs installed along the LINAC, with similar features as the ones of ELI-NP GBS, were used as measuring devices and signal sources for the read-out electronics under test. We present here the measurements collected and the related analysis, with a particular focus on the beam position measurement resolution.File | Dimensione | Formato | |
---|---|---|---|
Franzini_Measurements_2018.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
982.33 kB
Formato
Adobe PDF
|
982.33 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.