Introduction: Magnetic resonance imaging (MRI) studies obtained during the initial staging of patients affected by uterine cervical cancer were compared to the final histological report after surgery. Methods: Data were retrieved from published papers. Results: MRI detection of lymph node metastases shows a sensitivity of 49.3% (1209 patients) and a specificity of 87.7% (1182 patients). Parametrial involvement detection has 66.2% sensitivity (1288 patients) and 83.6% specificity (1282 patients). MRI tumor size evaluation shows significant error. Even detection of over 1 cm di- ameter primary tumor can fail. MRI appears promising in the detection of myometrial and endometrial involvement. Conclusions: Primary uterine cervical cancer evaluation with routine MRI has a limited accuracy especially in the de- tection of lymph node involvement and parametrial invasion. It is not sensitive enough to replace histology of dissected nodes and parametria. Tumor size estimation is imprecise. Detection of myometrial and endometrial invasion using MRI might be possible. Awareness of MRI limitations is crucial in primary cervical cancer staging.

Diagnostic Accuracy of MRI in Primary Cervical Cancer / Rigon, Giuliano; Vallone, Cristina; Starita, Andrea; Vismara, Marco Flavio Michele; Ialongo, Pasquale; Putignani, Lorenza; Signore, Fabrizio. - In: OPEN JOURNAL OF RADIOLOGY. - ISSN 2164-3032. - 02:01(2012), pp. 14-21. [10.4236/ojrad.2012.21003]

Diagnostic Accuracy of MRI in Primary Cervical Cancer

Vallone, Cristina;Vismara, Marco Flavio Michele;Ialongo, Pasquale;Putignani, Lorenza;
2012

Abstract

Introduction: Magnetic resonance imaging (MRI) studies obtained during the initial staging of patients affected by uterine cervical cancer were compared to the final histological report after surgery. Methods: Data were retrieved from published papers. Results: MRI detection of lymph node metastases shows a sensitivity of 49.3% (1209 patients) and a specificity of 87.7% (1182 patients). Parametrial involvement detection has 66.2% sensitivity (1288 patients) and 83.6% specificity (1282 patients). MRI tumor size evaluation shows significant error. Even detection of over 1 cm di- ameter primary tumor can fail. MRI appears promising in the detection of myometrial and endometrial involvement. Conclusions: Primary uterine cervical cancer evaluation with routine MRI has a limited accuracy especially in the de- tection of lymph node involvement and parametrial invasion. It is not sensitive enough to replace histology of dissected nodes and parametria. Tumor size estimation is imprecise. Detection of myometrial and endometrial invasion using MRI might be possible. Awareness of MRI limitations is crucial in primary cervical cancer staging.
2012
Cervical Cancer; MRI; Parametrial; Lymph Node Involvement
01 Pubblicazione su rivista::01a Articolo in rivista
Diagnostic Accuracy of MRI in Primary Cervical Cancer / Rigon, Giuliano; Vallone, Cristina; Starita, Andrea; Vismara, Marco Flavio Michele; Ialongo, Pasquale; Putignani, Lorenza; Signore, Fabrizio. - In: OPEN JOURNAL OF RADIOLOGY. - ISSN 2164-3032. - 02:01(2012), pp. 14-21. [10.4236/ojrad.2012.21003]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1181152
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact