Results of a national retrospective survey on Hyalomatrix PA in burn patients are reported. A total of 11 burn centers were contacted. A total of 57 patients were available. Hyalomatrix PA was used on young and adult patients, mainly in deep partial thickness and full thickness burns. In most cases, Hyalomatrix PA was applied immediately after the wound cleaning (wound debridement or escharectomy for adults, dermabrasion or debridement in young patients). After 7 days, reepithelization processes were more frequent in deep partial thickness burns. One-half of the patient population underwent grafting. After 29 days, complete closure was achieved in almost all patients. The Vancouver Scar Scale showed better values for adults, while no differences were observed for burn depth or patients undergoing grafting. No adverse reactions were recorded. Hyalomatrix PA is used in young and adults, in deep partial thickness and full thickness burns, as a temporary coverage before grafting or alone for wound healing.

Hyalomatrix PA in Burn Care Practice Results From a National Retrospective Survey, 2005 to 2006 / Gianpiero, Gravante; Roberto, Sorge; Antonio, Merone; Anna Maria, Tamisani; A., Di Lonardo; Alessandro, Scalise; Giovanna, Doneddu; Davide, Melandri; Giorgio, Stracuzzi; Onesti, Maria Giuseppina; Paolo, Cerulli; Raimondo, Pinna; Esposito, GAETANO FAUSTO. - In: ANNALS OF PLASTIC SURGERY. - ISSN 0148-7043. - 64:1(2010), pp. 69-79. [10.1097/sap.0b013e31819b3d59]

Hyalomatrix PA in Burn Care Practice Results From a National Retrospective Survey, 2005 to 2006

ONESTI, Maria Giuseppina;ESPOSITO, GAETANO FAUSTO
2010

Abstract

Results of a national retrospective survey on Hyalomatrix PA in burn patients are reported. A total of 11 burn centers were contacted. A total of 57 patients were available. Hyalomatrix PA was used on young and adult patients, mainly in deep partial thickness and full thickness burns. In most cases, Hyalomatrix PA was applied immediately after the wound cleaning (wound debridement or escharectomy for adults, dermabrasion or debridement in young patients). After 7 days, reepithelization processes were more frequent in deep partial thickness burns. One-half of the patient population underwent grafting. After 29 days, complete closure was achieved in almost all patients. The Vancouver Scar Scale showed better values for adults, while no differences were observed for burn depth or patients undergoing grafting. No adverse reactions were recorded. Hyalomatrix PA is used in young and adults, in deep partial thickness and full thickness burns, as a temporary coverage before grafting or alone for wound healing.
2010
tissue engineering; wound repair; biologic dressings; deep partial thickness burns; dermal substitutes
01 Pubblicazione su rivista::01a Articolo in rivista
Hyalomatrix PA in Burn Care Practice Results From a National Retrospective Survey, 2005 to 2006 / Gianpiero, Gravante; Roberto, Sorge; Antonio, Merone; Anna Maria, Tamisani; A., Di Lonardo; Alessandro, Scalise; Giovanna, Doneddu; Davide, Melandri; Giorgio, Stracuzzi; Onesti, Maria Giuseppina; Paolo, Cerulli; Raimondo, Pinna; Esposito, GAETANO FAUSTO. - In: ANNALS OF PLASTIC SURGERY. - ISSN 0148-7043. - 64:1(2010), pp. 69-79. [10.1097/sap.0b013e31819b3d59]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/116771
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 44
social impact