Purpose To assess image quality and accuracy of CT angiography (CTA) for transcatheter aortic valve replacement (TAVR) planning performed with 3rd generation dual-source CT (DSCT). Material and methods We evaluated 125 patients who underwent TAVR-planning CTA on 3rd generation DSCT. A two-part protocol was performed including retrospectively ECG-gated coronary CTA (CCTA) and prospectively ECG-triggered aortoiliac CTA using 60 mL of contrast medium. Automated tube voltage selection and advanced iterative reconstruction were applied. Effective dose (ED), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Five-point scales were used for subjective image quality analysis. In patients who underwent TAVR, sizing parameters were obtained. Results Image quality was rated good to excellent in 97.6% of CCTA and 100% of aortoiliac CTAs. CTA studies at >100 kV showed decreased objective image quality compared to 70–100 kV (SNR, all p ≤ 0.0459; CNR, all p ≤ 0.0462). Mean ED increased continuously from 70 to >100 kV (CCTA: 4.5 ± 1.7 mSv–13.6 ± 2.9 mSv, all p ≤ 0.0233; aortoiliac CTA: 2.4 ± 0.9 mSv–6.8 ± 2.7 mSv, all p ≤ 0.0414). In 39 patients TAVR was performed and annulus diameter was within the recommended range in all patients. No severe cardiac or vascular complications were noted. Conclusion 3rd generation DSCT provides diagnostic image quality in TAVR-planning CTA and facilitates reliable assessment of TAVR device and delivery option while reducing radiation dose.
CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: image quality and radiation exposure / Mangolda, Stefanie; De Cecco, Carlo N.; Joseph Schoepf, U.; Kuhlman, Taylor S.; Varga-Szemes, Akos; Caruso, Damiano; Duguay, Taylor M.; Tesche, Christian; Vogl, Thomas J.; Nikolaou, Konstantin; Steinberg, Daniel H.; Wichmann, Julian L.. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 86:(2017), pp. 276-283. [10.1016/j.ejrad.2016.11.023]
CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: image quality and radiation exposure
Carlo N. De Cecco;Damiano Caruso;
2017
Abstract
Purpose To assess image quality and accuracy of CT angiography (CTA) for transcatheter aortic valve replacement (TAVR) planning performed with 3rd generation dual-source CT (DSCT). Material and methods We evaluated 125 patients who underwent TAVR-planning CTA on 3rd generation DSCT. A two-part protocol was performed including retrospectively ECG-gated coronary CTA (CCTA) and prospectively ECG-triggered aortoiliac CTA using 60 mL of contrast medium. Automated tube voltage selection and advanced iterative reconstruction were applied. Effective dose (ED), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Five-point scales were used for subjective image quality analysis. In patients who underwent TAVR, sizing parameters were obtained. Results Image quality was rated good to excellent in 97.6% of CCTA and 100% of aortoiliac CTAs. CTA studies at >100 kV showed decreased objective image quality compared to 70–100 kV (SNR, all p ≤ 0.0459; CNR, all p ≤ 0.0462). Mean ED increased continuously from 70 to >100 kV (CCTA: 4.5 ± 1.7 mSv–13.6 ± 2.9 mSv, all p ≤ 0.0233; aortoiliac CTA: 2.4 ± 0.9 mSv–6.8 ± 2.7 mSv, all p ≤ 0.0414). In 39 patients TAVR was performed and annulus diameter was within the recommended range in all patients. No severe cardiac or vascular complications were noted. Conclusion 3rd generation DSCT provides diagnostic image quality in TAVR-planning CTA and facilitates reliable assessment of TAVR device and delivery option while reducing radiation dose.File | Dimensione | Formato | |
---|---|---|---|
angold_CT-anMgiography_2017.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.2 MB
Formato
Adobe PDF
|
1.2 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.