Ultrasound (US) is a relatively new imaging modality in rheumatology that offers great potential as a diagnostic and management tool. In 2004, an OMERACT Ultrasound Special Interest Group was formed to address the metric qualities of US as a potential outcome measure. A preliminary systematic review highlighted the deficiencies in the literature, particularly with regard to the reliability of interpreting and acquiring images; as a consequence, a number of exercises were proposed to address these issues. This report describes a series of iterative studies that have resulted in improved intra- and inter-reader reliability for detecting and scoring synovitis from both static and real-time images of the hand joints of patients with rheumatoid arthritis. The reliability of acquiring images was also enhanced using standardized positions. Future studies will assess the value of US in clinical trials.

The OMERACT ultrasound group: Status of current activities and research directions / R. J., Wakefield; M. A., D'Agostino; Iagnocco, Annamaria; E., Filippucci; M., Backhaus; A. K., Scheel; F., Joshua; E., Naredo; W. A., Schmidt; W., Grassi; I., Moller; C., Pineda; A., Klauser; M., Szkudlarek; L., Terslev; P., Balint; G. A. W., Bruyn; W. A. A., Swen; S., Jousse Joulin; D., Kane; J. M., Koski; P., O'Connor; S., Milutinovic; P. G., Conaghan. - In: THE JOURNAL OF RHEUMATOLOGY. - ISSN 0315-162X. - STAMPA. - 34:4(2007), pp. 848-851. (Intervento presentato al convegno 8th International Consensus Conference on Outcome Measures in Rheumatology Clinical Trails (OMERACT 8) tenutosi a St Julians Bay, MALTA nel MAY 10-14, 2006).

The OMERACT ultrasound group: Status of current activities and research directions

IAGNOCCO, Annamaria;
2007

Abstract

Ultrasound (US) is a relatively new imaging modality in rheumatology that offers great potential as a diagnostic and management tool. In 2004, an OMERACT Ultrasound Special Interest Group was formed to address the metric qualities of US as a potential outcome measure. A preliminary systematic review highlighted the deficiencies in the literature, particularly with regard to the reliability of interpreting and acquiring images; as a consequence, a number of exercises were proposed to address these issues. This report describes a series of iterative studies that have resulted in improved intra- and inter-reader reliability for detecting and scoring synovitis from both static and real-time images of the hand joints of patients with rheumatoid arthritis. The reliability of acquiring images was also enhanced using standardized positions. Future studies will assess the value of US in clinical trials.
2007
inflammatory arthritis; reliability; ultrasonography; validity
01 Pubblicazione su rivista::01a Articolo in rivista
The OMERACT ultrasound group: Status of current activities and research directions / R. J., Wakefield; M. A., D'Agostino; Iagnocco, Annamaria; E., Filippucci; M., Backhaus; A. K., Scheel; F., Joshua; E., Naredo; W. A., Schmidt; W., Grassi; I., Moller; C., Pineda; A., Klauser; M., Szkudlarek; L., Terslev; P., Balint; G. A. W., Bruyn; W. A. A., Swen; S., Jousse Joulin; D., Kane; J. M., Koski; P., O'Connor; S., Milutinovic; P. G., Conaghan. - In: THE JOURNAL OF RHEUMATOLOGY. - ISSN 0315-162X. - STAMPA. - 34:4(2007), pp. 848-851. (Intervento presentato al convegno 8th International Consensus Conference on Outcome Measures in Rheumatology Clinical Trails (OMERACT 8) tenutosi a St Julians Bay, MALTA nel MAY 10-14, 2006).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/116254
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 20
  • Scopus 117
  • ???jsp.display-item.citation.isi??? 109
social impact