Immune compromised as well as critically ill patients are at higher risk of surgical wound infection and dehiscence. Wound infections critically influence the outcomes after liver transplantation. In particular, it was shown that they significantly reduce the overall survival rate when compared to patients with uneventful wound healing, and their occurrence is associated with death or graft loss within 1-year post-transplantation. From January 2001 through December 2017, 763 patients underwent liver transplantation in our Institution, the Hepato-Pancreato-Biliary Surgery and Liver Transplantation Unit, "Policlinico" University Hospital, University of Modena and Reggio Emilia, Modena, Italy. We retrospectively analyzed data from our prospectively maintained database of patients treated with a negative pressure therapy device due to wound or abdominal infections. 13 patients underwent negative pressure treatments for surgical site infection after liver transplantation in our institution. Ten superficial "supra-fascial" applications (SF group) and three deeper abdominal (Ab group) were reported. Mean in-hospital stay for the SF group was 42.6 days, ranging from 8 to 80, while for the Ab group was 62 days (range 23-133), with an overall survival of 34 and 4.6 months, respectively. A multifactorial multidisciplinary approach is needed in the prevention of surgical site infections instead of mere antimicrobial prophylaxis The application of negative pressure wound therapy may help in controlling the diffusion of the infection and preventing sepsis.

Vacuum-assisted management of surgical site infections after liver transplantation: 15-year experience in a tertiary hepatobiliary center / Magistri, P; Olivieri, T; Serra, V; Tarantino, G; Assirati, G; Pecchi, A; Ballarin, R; Di Benedetto, F. - In: UPDATES IN SURGERY. - ISSN 2038-131X. - (2018). [10.1007/s13304-018-0583-8]

Vacuum-assisted management of surgical site infections after liver transplantation: 15-year experience in a tertiary hepatobiliary center

Magistri P;
2018

Abstract

Immune compromised as well as critically ill patients are at higher risk of surgical wound infection and dehiscence. Wound infections critically influence the outcomes after liver transplantation. In particular, it was shown that they significantly reduce the overall survival rate when compared to patients with uneventful wound healing, and their occurrence is associated with death or graft loss within 1-year post-transplantation. From January 2001 through December 2017, 763 patients underwent liver transplantation in our Institution, the Hepato-Pancreato-Biliary Surgery and Liver Transplantation Unit, "Policlinico" University Hospital, University of Modena and Reggio Emilia, Modena, Italy. We retrospectively analyzed data from our prospectively maintained database of patients treated with a negative pressure therapy device due to wound or abdominal infections. 13 patients underwent negative pressure treatments for surgical site infection after liver transplantation in our institution. Ten superficial "supra-fascial" applications (SF group) and three deeper abdominal (Ab group) were reported. Mean in-hospital stay for the SF group was 42.6 days, ranging from 8 to 80, while for the Ab group was 62 days (range 23-133), with an overall survival of 34 and 4.6 months, respectively. A multifactorial multidisciplinary approach is needed in the prevention of surgical site infections instead of mere antimicrobial prophylaxis The application of negative pressure wound therapy may help in controlling the diffusion of the infection and preventing sepsis.
2018
SSI; VAC; vacuum therapy; vacuum-assisted closure; vacuum-assisted therapy; wound healing
01 Pubblicazione su rivista::01a Articolo in rivista
Vacuum-assisted management of surgical site infections after liver transplantation: 15-year experience in a tertiary hepatobiliary center / Magistri, P; Olivieri, T; Serra, V; Tarantino, G; Assirati, G; Pecchi, A; Ballarin, R; Di Benedetto, F. - In: UPDATES IN SURGERY. - ISSN 2038-131X. - (2018). [10.1007/s13304-018-0583-8]
File allegati a questo prodotto
File Dimensione Formato  
Magistri_Vacuum-therapy.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.17 MB
Formato Adobe PDF
1.17 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1158839
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact