QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel4He sorption cooler and a double-stage3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.

Thermal architecture for the QUBIC cryogenic receiver / May, A. J.; Chapron, C.; Coppi, G.; D'Alessandro, G.; De Bernardis, P.; Masi, S.; Melhuish, S.; Piat, M.; Piccirillo, L.; Schillaci, A.; Thermeau, J. -P.; Ade, P.; Amico, G.; Auguste, D.; Aumont, J.; Banfi, S.; Barbarán, G.; Battaglia, P.; Battistelli, E.; Baù, A.; Bélier, B.; Bennett, D.; Bergé, L.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bleurvacq, N.; Bonaparte, J.; Bonis, J.; Bordier, G.; Bréelle, E.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Charlassier, R.; Columbro, F.; Coppolecchia, A.; Couchot, F.; D'Agostino, R.; De Gasperis, G.; De Leo, M.; De Petris, M.; Di Donato, A.; Dumoulin, L.; Etchegoyen, A.; Fasciszewski, A.; Franceschet, C.; Gamboa Lerena, M. M.; García, B.; Garrido, X.; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Giraud-Héraud, Y.; Gómez Berisso, M.; González, M.; Gradziel, M.; Grandsire, L.; Guerrard, E.; Hamilton, J. -Ch.; Harari, D.; Haynes, V.; Henrot-Versillé, S.; Hoang, D. T.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Lowitz, A.; Lukovic, V.; Luterstein, R.; Maffei, B.; Marnieros, S.; Mattei, A.; McCulloch, M. A.; Medina, M. C.; Mele, L.; Mennella, A.; Montier, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; O'Sullivan, C.; Olivieri, E.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perbost, C.; Perdereau, O.; Pezzotta, F.; Piacentini, F.; Pisano, G.; Polenta, G.; Prêle, D.; Puddu, R.; Rambaud, D.; Ringegni, P.; Romero, G. E.; Salatino, M.; Scóccola, C. G.; Scully, S.; Spinelli, S.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Timbie, P.; Torchinsky, S. A.; Tristram, M.; Truongcanh, V.; Tucker, C.; Tucker, G.; Vanneste, S.; Viganó, D.; Vittorio, N.; Voisin, F.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.. - STAMPA. - 10708:(2018), p. 130. (Intervento presentato al convegno Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX 2018 tenutosi a usa) [10.1117/12.2312085].

Thermal architecture for the QUBIC cryogenic receiver

D'Alessandro, G.;De Bernardis, P.;Masi, S.;Amico, G.;Battistelli, E.;Buzzelli, A.;Columbro, F.;Coppolecchia, A.;De Gasperis, G.;De Petris, M.;Lamagna, L.;Mele, L.;Paiella, A.;Piacentini, F.;Pisano, G.;
2018

Abstract

QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel4He sorption cooler and a double-stage3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
2018
Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX 2018
bolometric interferometry; cryogenics; experimental cosmology; heat switch; QUBIC; sorption cooler; Electronic, Optical and Magnetic Materials; Condensed Matter Physics; Computer Science Applications1707 Computer Vision and Pattern Recognition; Applied Mathematics; Electrical and Electronic Engineering
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Thermal architecture for the QUBIC cryogenic receiver / May, A. J.; Chapron, C.; Coppi, G.; D'Alessandro, G.; De Bernardis, P.; Masi, S.; Melhuish, S.; Piat, M.; Piccirillo, L.; Schillaci, A.; Thermeau, J. -P.; Ade, P.; Amico, G.; Auguste, D.; Aumont, J.; Banfi, S.; Barbarán, G.; Battaglia, P.; Battistelli, E.; Baù, A.; Bélier, B.; Bennett, D.; Bergé, L.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bleurvacq, N.; Bonaparte, J.; Bonis, J.; Bordier, G.; Bréelle, E.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Charlassier, R.; Columbro, F.; Coppolecchia, A.; Couchot, F.; D'Agostino, R.; De Gasperis, G.; De Leo, M.; De Petris, M.; Di Donato, A.; Dumoulin, L.; Etchegoyen, A.; Fasciszewski, A.; Franceschet, C.; Gamboa Lerena, M. M.; García, B.; Garrido, X.; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Giraud-Héraud, Y.; Gómez Berisso, M.; González, M.; Gradziel, M.; Grandsire, L.; Guerrard, E.; Hamilton, J. -Ch.; Harari, D.; Haynes, V.; Henrot-Versillé, S.; Hoang, D. T.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Lowitz, A.; Lukovic, V.; Luterstein, R.; Maffei, B.; Marnieros, S.; Mattei, A.; McCulloch, M. A.; Medina, M. C.; Mele, L.; Mennella, A.; Montier, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; O'Sullivan, C.; Olivieri, E.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perbost, C.; Perdereau, O.; Pezzotta, F.; Piacentini, F.; Pisano, G.; Polenta, G.; Prêle, D.; Puddu, R.; Rambaud, D.; Ringegni, P.; Romero, G. E.; Salatino, M.; Scóccola, C. G.; Scully, S.; Spinelli, S.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Timbie, P.; Torchinsky, S. A.; Tristram, M.; Truongcanh, V.; Tucker, C.; Tucker, G.; Vanneste, S.; Viganó, D.; Vittorio, N.; Voisin, F.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.. - STAMPA. - 10708:(2018), p. 130. (Intervento presentato al convegno Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX 2018 tenutosi a usa) [10.1117/12.2312085].
File allegati a questo prodotto
File Dimensione Formato  
May_Thermal_2018.pdf

solo gestori archivio

Note: https://www.spiedigitallibrary.org/conference-proceedings-of-spie/10708/2312085/Thermal-architecture-for-the-QUBIC-cryogenic-receiver/10.1117/12.2312085.short
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 3.01 MB
Formato Adobe PDF
3.01 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1153406
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 4
social impact