Objectives: To investigate the minimum iodine delivery rate (IDR) required to achieve diagnostic coronary attenuation (300 HU) with dual-energy coronary CTA. Methods: Acquisitions were performed on a circulation phantom with a third- generation dual-source CT scanner. Contrast media was injected for a fixed time whilst IDRs varied from 1.0 to 0.3 gI/s in 0.1-gI/s intervals. Noise-optimized virtual monoenergetic imaging (VMI+) reconstructions from 40 to 90 keV in 5 keV increments were generated. Contrast-to-noise ratio (CNR) and coronary HU were measured for each injection. Results: VMI+ from 40–70 keV reached diagnostic attenuation with at least one IDR. The minimum IDR achieving a diagnostic attenuation ranged from 0.4 gI/s at 40 keV (312.8 HU) to 1.0 gI/s at 70 keV (334.1 HU). Attenuation values reached with IDR of 1.0 gI/s were significantly higher at each keV level (p<0.001). CNR showed a near perfect correlation with the IDR (ρ≥0.962; p<0.001), the IDR of 1.0 gI/s provided the highest CNR at each keV level, achieving the highest overall value at 40 keV (54.0±3.1). Conclusions: IDRs from 0.4–1.0 gI/s associated with VMI+ from 40–70 keV provide diagnostic coronary attenuation with dual-energy coronary CTA. Key Points: • Iodine delivery rate (IDR) is a major determinant of contrast enhancement. • Low-keV noise-optimized monoenergetic images (VMI+) maximize iodine attenuation. • Low-keV VMI+ allows for lower IDRs while maintaining adequate coronary attenuation. • Lowest IDR to reach 300 HU was 0.4 gI/s, 40 keV VMI+.

Contrast media injection protocol optimization for dual-energy coronary CT angiography. results from a circulation phantom / De Santis, Domenico; Caruso, Damiano; Schoepf, U Joseph; Eid, Marwen; Albrecht, Moritz H; Duguay, Taylor M; Varga-Szemes, Akos; Laghi, Andrea; De Cecco, Carlo N. - In: EUROPEAN RADIOLOGY. - ISSN 1432-1084. - 28:8(2018), pp. 3473-3481. [10.1007/s00330-018-5308-3]

Contrast media injection protocol optimization for dual-energy coronary CT angiography. results from a circulation phantom

De Santis, Domenico;Caruso, Damiano;Laghi, Andrea;De Cecco, Carlo N
2018

Abstract

Objectives: To investigate the minimum iodine delivery rate (IDR) required to achieve diagnostic coronary attenuation (300 HU) with dual-energy coronary CTA. Methods: Acquisitions were performed on a circulation phantom with a third- generation dual-source CT scanner. Contrast media was injected for a fixed time whilst IDRs varied from 1.0 to 0.3 gI/s in 0.1-gI/s intervals. Noise-optimized virtual monoenergetic imaging (VMI+) reconstructions from 40 to 90 keV in 5 keV increments were generated. Contrast-to-noise ratio (CNR) and coronary HU were measured for each injection. Results: VMI+ from 40–70 keV reached diagnostic attenuation with at least one IDR. The minimum IDR achieving a diagnostic attenuation ranged from 0.4 gI/s at 40 keV (312.8 HU) to 1.0 gI/s at 70 keV (334.1 HU). Attenuation values reached with IDR of 1.0 gI/s were significantly higher at each keV level (p<0.001). CNR showed a near perfect correlation with the IDR (ρ≥0.962; p<0.001), the IDR of 1.0 gI/s provided the highest CNR at each keV level, achieving the highest overall value at 40 keV (54.0±3.1). Conclusions: IDRs from 0.4–1.0 gI/s associated with VMI+ from 40–70 keV provide diagnostic coronary attenuation with dual-energy coronary CTA. Key Points: • Iodine delivery rate (IDR) is a major determinant of contrast enhancement. • Low-keV noise-optimized monoenergetic images (VMI+) maximize iodine attenuation. • Low-keV VMI+ allows for lower IDRs while maintaining adequate coronary attenuation. • Lowest IDR to reach 300 HU was 0.4 gI/s, 40 keV VMI+.
2018
computed tomography angiography; contrast media; coronary angiography; dual-energy scanned projection radiography; radiological phantom
01 Pubblicazione su rivista::01a Articolo in rivista
Contrast media injection protocol optimization for dual-energy coronary CT angiography. results from a circulation phantom / De Santis, Domenico; Caruso, Damiano; Schoepf, U Joseph; Eid, Marwen; Albrecht, Moritz H; Duguay, Taylor M; Varga-Szemes, Akos; Laghi, Andrea; De Cecco, Carlo N. - In: EUROPEAN RADIOLOGY. - ISSN 1432-1084. - 28:8(2018), pp. 3473-3481. [10.1007/s00330-018-5308-3]
File allegati a questo prodotto
File Dimensione Formato  
DeSantis_Contrast_2018.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.5 MB
Formato Adobe PDF
1.5 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1143591
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact