The paper deals with the protective relaying of MV rings recently introduced by e-distribuzione, the largest Italian Distribution System Operator (DSO). The paper refers to an existing MV distribution system which includes a loop line. Attention is focused on Cross-Country Faults (CCFs), i.e. two Line-to-Ground Faults simultaneously occurring in two different phases at different locations. A large number of detailed ATP-EMTP simulations of CCFs are carried out, evidencing a few critical CCF combinations not detected by the presently adopted protective relays. Results point out that such maloperations only occur in mixed overhead-cable rings, while all-cable loop lines are not affected. Lastly, it is also shown that CCF detection is not a problem in mixed overhead-cable rings if the overhead lines are equipped with a ground conductor. The above results could be taken as guidelines for new ring lines.
Detection of cross-country faults in medium voltage distribution ring lines / Codino, Asia; Gatta, Fabio Massimo; Geri, Alberto; Lauria, Stefano; Maccioni, Marco; Calone, Roberto. - 2017-:(2017), pp. 1-6. (Intervento presentato al convegno 2017 AEIT International Annual Conference, AEIT 2017 tenutosi a ita) [10.23919/AEIT.2017.8240493].
Detection of cross-country faults in medium voltage distribution ring lines
Codino, Asia;Gatta, Fabio Massimo;Geri, Alberto;Lauria, Stefano;Maccioni, Marco;
2017
Abstract
The paper deals with the protective relaying of MV rings recently introduced by e-distribuzione, the largest Italian Distribution System Operator (DSO). The paper refers to an existing MV distribution system which includes a loop line. Attention is focused on Cross-Country Faults (CCFs), i.e. two Line-to-Ground Faults simultaneously occurring in two different phases at different locations. A large number of detailed ATP-EMTP simulations of CCFs are carried out, evidencing a few critical CCF combinations not detected by the presently adopted protective relays. Results point out that such maloperations only occur in mixed overhead-cable rings, while all-cable loop lines are not affected. Lastly, it is also shown that CCF detection is not a problem in mixed overhead-cable rings if the overhead lines are equipped with a ground conductor. The above results could be taken as guidelines for new ring lines.File | Dimensione | Formato | |
---|---|---|---|
Codino_Detection_2017.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
721.3 kB
Formato
Adobe PDF
|
721.3 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.