Objectives: To evaluate long-term benefits of a totally implantable active middle ear implant (AMEI) that has been used in a single implanting center for over 10 years. Methods: Forty-one subjects who underwent implantation with an Esteem® AMEI during a 10-years period were evaluated on the auditory benefits, as derived from pure tone and speech audiometry tests. The analysis included a comparison with a conventional hearing aid, the problematics related to the battery duration and surgical replacement and, finally, the complication rate. Results: Over 80% of the implanted subjects maintained over time a satisfactory auditory gain, ranging from 10 to over 30 dB in respect to the unaided situation, as mean at 0.5, 1, 2 and 4 kHz. In more than 60% of them, an improvement has also been found at 4 and 8 kHz. Battery duration varied according to the severity of the hearing loss and to the daily use of the device. No major post-operative complications were recorded, whilst explantation was necessary in five subjects, although none for device failure. Conclusions: The Esteem® can be considered a reliable device for rehabilitation of sensorineural hearing loss in alternative to conventional hearing aids.
Ten years of active middle ear implantation for sensorineural hearing loss / Barbara, M.; Filippi, C.; Covelli, E.; Volpini, L.; Monini, S.. - In: ACTA OTO-LARYNGOLOGICA. - ISSN 0001-6489. - ELETTRONICO. - 138:9(2018), pp. 1-9. [10.1080/00016489.2018.1472807]
Ten years of active middle ear implantation for sensorineural hearing loss
M. Barbara
Writing – Review & Editing
;C. FilippiData Curation
;E. CovelliData Curation
;L. VolpiniMethodology
;S. MoniniSupervision
2018
Abstract
Objectives: To evaluate long-term benefits of a totally implantable active middle ear implant (AMEI) that has been used in a single implanting center for over 10 years. Methods: Forty-one subjects who underwent implantation with an Esteem® AMEI during a 10-years period were evaluated on the auditory benefits, as derived from pure tone and speech audiometry tests. The analysis included a comparison with a conventional hearing aid, the problematics related to the battery duration and surgical replacement and, finally, the complication rate. Results: Over 80% of the implanted subjects maintained over time a satisfactory auditory gain, ranging from 10 to over 30 dB in respect to the unaided situation, as mean at 0.5, 1, 2 and 4 kHz. In more than 60% of them, an improvement has also been found at 4 and 8 kHz. Battery duration varied according to the severity of the hearing loss and to the daily use of the device. No major post-operative complications were recorded, whilst explantation was necessary in five subjects, although none for device failure. Conclusions: The Esteem® can be considered a reliable device for rehabilitation of sensorineural hearing loss in alternative to conventional hearing aids.File | Dimensione | Formato | |
---|---|---|---|
Barbara_Ten-years_2018.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.37 MB
Formato
Adobe PDF
|
1.37 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.