In this paper, the design and characterization of a device, able to analyze the electrical bio-impedance in the frequency domain and its variations with time, is presented. The whole system design, that employs a tetra-polar electrode configuration, a specifically developed printed circuit board, and a data acquisition card connected to a PC, is presented. The measurement system is controlled through LabVIEW virtual instruments. Different reference resistors and RC networks, with impedance values lying in the physiological range of bio-impedances, have been used for assessing the systematic and random uncertainty contributions, and to derive the calibration curves necessary to correct the systematic effects of the developed instrument. The obtained results show that it is possible to achieve excellent metrological performances with the proposed system, that is suitable to be developed in a low-cost and portable version. Two possible applications of the instrument are shown, i.e. cardiorespiratory activity monitoring and bioelectrical impedance spectroscopy.

Metrological characterization of a combined bio-impedance plethysmograph and spectrometer / Pittella, E.; Piuzzi, E.; Rizzuto, E.; Pisa, S.; Del Prete, Z.. - In: MEASUREMENT. - ISSN 0263-2241. - STAMPA. - 120:(2018), pp. 221-229. [10.1016/j.measurement.2018.02.032]

Metrological characterization of a combined bio-impedance plethysmograph and spectrometer

E. Pittella
;
E. Piuzzi;E. Rizzuto;S. Pisa;Z. Del Prete
2018

Abstract

In this paper, the design and characterization of a device, able to analyze the electrical bio-impedance in the frequency domain and its variations with time, is presented. The whole system design, that employs a tetra-polar electrode configuration, a specifically developed printed circuit board, and a data acquisition card connected to a PC, is presented. The measurement system is controlled through LabVIEW virtual instruments. Different reference resistors and RC networks, with impedance values lying in the physiological range of bio-impedances, have been used for assessing the systematic and random uncertainty contributions, and to derive the calibration curves necessary to correct the systematic effects of the developed instrument. The obtained results show that it is possible to achieve excellent metrological performances with the proposed system, that is suitable to be developed in a low-cost and portable version. Two possible applications of the instrument are shown, i.e. cardiorespiratory activity monitoring and bioelectrical impedance spectroscopy.
2018
bioelectrical impedance spectroscopy; bioimpedance; measurement uncertainty; plethysmography; portable device
01 Pubblicazione su rivista::01a Articolo in rivista
Metrological characterization of a combined bio-impedance plethysmograph and spectrometer / Pittella, E.; Piuzzi, E.; Rizzuto, E.; Pisa, S.; Del Prete, Z.. - In: MEASUREMENT. - ISSN 0263-2241. - STAMPA. - 120:(2018), pp. 221-229. [10.1016/j.measurement.2018.02.032]
File allegati a questo prodotto
File Dimensione Formato  
Pittella_Metrological_2018.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 872.19 kB
Formato Adobe PDF
872.19 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1097095
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact