Continuous monitoring has been carried out at a fluvial flood-plain site near Rome for over a year. There is a mix of biogenic CO2 and deep geogenic CO2 at the site at relatively low concentrations and fluxes compared with other natural CO2 seepage sites studied previously. Factors such as temperature and soil moisture clearly affect the CO2 concentration and flux and seasonal and diurnal influences are apparent. Statistical approaches are being used to try to define these relationships and separate out the two gas components, which would be necessary in any quantification of leakage from CO2 storage.

Continuous monitoring of natural CO2 emissions near Rome. Lessons for low-level CO2 leakage detection / Jones, David G.; Beaubien, Stanley E.; Lister, T. Robert; Graziani, Stefano; Finoia, Maria Grazia; Barkwith, Andrew Kap; Ruggiero, Livio; Ciotoli, Giancarlo; Bigi, Sabina; Lombardi, Salvatore. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - ELETTRONICO. - 114:(2017), pp. 3824-3831. [10.1016/j.egypro.2017.03.1514]

Continuous monitoring of natural CO2 emissions near Rome. Lessons for low-level CO2 leakage detection

Beaubien, Stanley E.;Graziani, Stefano;Ruggiero, Livio;Ciotoli, Giancarlo;Bigi, Sabina;Lombardi, Salvatore
2017

Abstract

Continuous monitoring has been carried out at a fluvial flood-plain site near Rome for over a year. There is a mix of biogenic CO2 and deep geogenic CO2 at the site at relatively low concentrations and fluxes compared with other natural CO2 seepage sites studied previously. Factors such as temperature and soil moisture clearly affect the CO2 concentration and flux and seasonal and diurnal influences are apparent. Statistical approaches are being used to try to define these relationships and separate out the two gas components, which would be necessary in any quantification of leakage from CO2 storage.
2017
continuous monitoring; flux; leakage; natural CO2 release; soil gas; energy (all)
01 Pubblicazione su rivista::01a Articolo in rivista
Continuous monitoring of natural CO2 emissions near Rome. Lessons for low-level CO2 leakage detection / Jones, David G.; Beaubien, Stanley E.; Lister, T. Robert; Graziani, Stefano; Finoia, Maria Grazia; Barkwith, Andrew Kap; Ruggiero, Livio; Ciotoli, Giancarlo; Bigi, Sabina; Lombardi, Salvatore. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - ELETTRONICO. - 114:(2017), pp. 3824-3831. [10.1016/j.egypro.2017.03.1514]
File allegati a questo prodotto
File Dimensione Formato  
Jones_Continuous_2017.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 462.98 kB
Formato Adobe PDF
462.98 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1093946
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact