Electron spin resonance (ESR) is a spectroscopic method that allows to measure stable radicals induced by ionizing radiation. The EPR measurements can help to estimate the dose absorbed by people exposed during a nuclear disaster, detecting the number of radicals induced in their mobile phones due to the exposition [1]. Using conventional closed microwave cavities, the phone display must be fragmented in order to be introduced inside the resonator, becoming no more usable. The aim of this work is to develop a system, compatible with the spectrometer Bruker Elexys E500, able to preserve the sample integrity. The system uses an X-band resonant metallic cavity with a slit, realized on one side, for the leak of the excitation magnetic field and a Helmotz coil pair. The resonator allows measuring a sample lodged outside the cavity, while the coils produce a 100 kHz modulated field that encodes the output signal at a particular frequency and increases the SNR.

Measurement results and improvements on an open EPR system / Sacco, Giulia; De Angelis, C.; De Angelis, G.; Della Monaca, S.; DI TROCCHIO, PIER LUIGI; Fattibene, P.; Ficcadenti, L.; Lucentini, M.; Mostacci, A.; Piersanti, L.; Pisa, S.; Pittella, E.; Quattrini, M. C.; Santavenere, F.. - ELETTRONICO. - (2017). (Intervento presentato al convegno Biophysics@Rome 2017 tenutosi a Rome nel May 18-19 2017).

Measurement results and improvements on an open EPR system

SACCO, Giulia;L. Ficcadenti;M. Lucentini;A. Mostacci;S. Pisa;E. Pittella;
2017

Abstract

Electron spin resonance (ESR) is a spectroscopic method that allows to measure stable radicals induced by ionizing radiation. The EPR measurements can help to estimate the dose absorbed by people exposed during a nuclear disaster, detecting the number of radicals induced in their mobile phones due to the exposition [1]. Using conventional closed microwave cavities, the phone display must be fragmented in order to be introduced inside the resonator, becoming no more usable. The aim of this work is to develop a system, compatible with the spectrometer Bruker Elexys E500, able to preserve the sample integrity. The system uses an X-band resonant metallic cavity with a slit, realized on one side, for the leak of the excitation magnetic field and a Helmotz coil pair. The resonator allows measuring a sample lodged outside the cavity, while the coils produce a 100 kHz modulated field that encodes the output signal at a particular frequency and increases the SNR.
2017
Biophysics@Rome 2017
EPR; open resonator; modulation coil; resonance
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Measurement results and improvements on an open EPR system / Sacco, Giulia; De Angelis, C.; De Angelis, G.; Della Monaca, S.; DI TROCCHIO, PIER LUIGI; Fattibene, P.; Ficcadenti, L.; Lucentini, M.; Mostacci, A.; Piersanti, L.; Pisa, S.; Pittella, E.; Quattrini, M. C.; Santavenere, F.. - ELETTRONICO. - (2017). (Intervento presentato al convegno Biophysics@Rome 2017 tenutosi a Rome nel May 18-19 2017).
File allegati a questo prodotto
File Dimensione Formato  
Sacco_Measurement_2017.pdf

accesso aperto

Tipologia: Documento in Pre-print (manoscritto inviato all'editore, precedente alla peer review)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 445.13 kB
Formato Adobe PDF
445.13 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1092637
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact