The trans-venous implantable cardioverter defibrillator (TV-ICD) is effective in treating life-threatening ventricular arrhythmia and reduces mortality in high-risk patients. However, there are significant short- and long-term complications that are associated with intravascular leads. These shortcomings are mostly relevant in young patients with long life expectancy and low risk of death from non-arrhythmic causes. Drawbacks of trans-venous leads recently led to the development of the entirely subcutaneous implantable cardioverter defibrillator (S-ICD). The S-ICD does not require vascular access or permanent intravascular defibrillation leads. Therefore, it is expected to overcome many complications associated with conventional ICDs. This review highlights data on safety and efficacy of the S-ICD and is envisioned to help in identifying the role of this device in clinical practice.

Safety, Efficacy and Evidence Base for Use of the Subcutaneous Implantable Cardioverter Defibrillator / Adduci, Carmen; Palano, Francesca; Francia, Pietro. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - STAMPA. - 7:3(2018), pp. 1-10. [10.3390/jcm7030053]

Safety, Efficacy and Evidence Base for Use of the Subcutaneous Implantable Cardioverter Defibrillator

Adduci, Carmen;Palano, Francesca;Francia, Pietro
2018

Abstract

The trans-venous implantable cardioverter defibrillator (TV-ICD) is effective in treating life-threatening ventricular arrhythmia and reduces mortality in high-risk patients. However, there are significant short- and long-term complications that are associated with intravascular leads. These shortcomings are mostly relevant in young patients with long life expectancy and low risk of death from non-arrhythmic causes. Drawbacks of trans-venous leads recently led to the development of the entirely subcutaneous implantable cardioverter defibrillator (S-ICD). The S-ICD does not require vascular access or permanent intravascular defibrillation leads. Therefore, it is expected to overcome many complications associated with conventional ICDs. This review highlights data on safety and efficacy of the S-ICD and is envisioned to help in identifying the role of this device in clinical practice.
2018
subcutaneous icd; sudden cardiac death; transvenous leads
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
Safety, Efficacy and Evidence Base for Use of the Subcutaneous Implantable Cardioverter Defibrillator / Adduci, Carmen; Palano, Francesca; Francia, Pietro. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - STAMPA. - 7:3(2018), pp. 1-10. [10.3390/jcm7030053]
File allegati a questo prodotto
File Dimensione Formato  
Adduci_Safety_2018.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Creative commons
Dimensione 462.67 kB
Formato Adobe PDF
462.67 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1091941
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact