Patient-specific instruments (PSI) has been introduced with the aim to reduce the overall costs of the implants, minimizing the size and number of instruments required, and also reducing surgery time. The aim of this study was to perform a review of the current literature, as well as to report about our personal experience, to assess reliability and accuracy of patient specific instrument system in total knee arthroplasty (TKA). A literature review was conducted of PSI system reviewing articles related to coronal alignment, clinical knee and function scores, cost, patient satisfaction and complications. Studies have reported incidences of coronal alignment ≥3° from neutral in TKAs performed with patient-specific cutting guides ranging from 6% to 31%. PSI seem not to be able to result in the same degree of accuracy as for the CAS system, while comparing well with standard manual technique with respect to component positioning and overall lower axis, in particular in the sagittal plane. In cases in which custom-made cutting jigs were used, we recommend performing an accurate control of the alignment before and after any cuts and in any further step of the procedure, in order to avoid possible outliers.

Evaluation of the accuracy of a patient-specific instrumentation / Mazza, Daniele; Iorio, Raffaele; Guzzini, Matteo; Redler, Andrea; Conteduca, Fabio; Ferretti, Andrea. - In: MINERVA ORTOPEDICA E TRAUMATOLOGICA. - ISSN 1827-1707. - ELETTRONICO. - 68:1(2017), pp. 42-50. [10.23736/S0026-4911.16.03782-4]

Evaluation of the accuracy of a patient-specific instrumentation

Mazza, Daniele
;
Iorio, Raffaele;Guzzini, Matteo;Redler, Andrea;Conteduca, Fabio;Ferretti, Andrea
2017

Abstract

Patient-specific instruments (PSI) has been introduced with the aim to reduce the overall costs of the implants, minimizing the size and number of instruments required, and also reducing surgery time. The aim of this study was to perform a review of the current literature, as well as to report about our personal experience, to assess reliability and accuracy of patient specific instrument system in total knee arthroplasty (TKA). A literature review was conducted of PSI system reviewing articles related to coronal alignment, clinical knee and function scores, cost, patient satisfaction and complications. Studies have reported incidences of coronal alignment ≥3° from neutral in TKAs performed with patient-specific cutting guides ranging from 6% to 31%. PSI seem not to be able to result in the same degree of accuracy as for the CAS system, while comparing well with standard manual technique with respect to component positioning and overall lower axis, in particular in the sagittal plane. In cases in which custom-made cutting jigs were used, we recommend performing an accurate control of the alignment before and after any cuts and in any further step of the procedure, in order to avoid possible outliers.
2017
arthroplasty, replacement, knee; implants; operative; surgical procedures; surgery; orthopedics and sports medicine
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
Evaluation of the accuracy of a patient-specific instrumentation / Mazza, Daniele; Iorio, Raffaele; Guzzini, Matteo; Redler, Andrea; Conteduca, Fabio; Ferretti, Andrea. - In: MINERVA ORTOPEDICA E TRAUMATOLOGICA. - ISSN 1827-1707. - ELETTRONICO. - 68:1(2017), pp. 42-50. [10.23736/S0026-4911.16.03782-4]
File allegati a questo prodotto
File Dimensione Formato  
Mazza_Evaluation_2017.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF
Mazza_Evaluation_2017.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 931.96 kB
Formato Adobe PDF
931.96 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1086111
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact