In high-brightness LINear ACcelerators (LINACs), electron bunch length can be measured indirectly by a radio frequency deflector (RFD). In this paper, the accuracy loss arising from non-negligible correlations between particle longitudinal positions and the transverse plane (in particular the vertical one) at RFD entrance is analytically assessed. Theoretical predictions are compared with simulation results, obtained by means of ELEctron Generation ANd Tracking (ELEGANT) code, in the case study of the gamma beam system (GBS) at the extreme light infrastructure—nuclear physics (ELI-NP). In particular, the relative error affecting the bunch length measurement, for bunches characterized by both energy chirp and fixed correlation coefficients between longitudinal particle positions and the vertical plane, is reported. Moreover, the relative error versus the correlation coefficients is shown for fixed RFD phase 0 rad and π rad. The relationship between relative error and correlations factors can help the decision of using the bunch length measurement technique with one or two vertical spot size measurements in order to cancel the correlations contribution. In the case of the GBS electron LINAC, the misalignment of one of the quadrupoles before the RFD between −2 mm and 2 mm leads to a relative error less than 5%. The misalignment of the first C-band accelerating section between −2 mm and 2 mm could lead to a relative error up to 10%.

Effects of correlations between particle longitudinal positions and transverse plane on bunch length measurement: A case study on GBS electron LINAC at ELI-NP / Sabato, L.; Arpaia, P.; Cianchi, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Variola, A.. - In: MEASUREMENT SCIENCE & TECHNOLOGY. - ISSN 0957-0233. - ELETTRONICO. - 29:2(2018), p. 024005. [10.1088/1361-6501/aaa281]

Effects of correlations between particle longitudinal positions and transverse plane on bunch length measurement: A case study on GBS electron LINAC at ELI-NP

Sabato, L.
;
Mostacci, A.;Palumbo, L.;
2018

Abstract

In high-brightness LINear ACcelerators (LINACs), electron bunch length can be measured indirectly by a radio frequency deflector (RFD). In this paper, the accuracy loss arising from non-negligible correlations between particle longitudinal positions and the transverse plane (in particular the vertical one) at RFD entrance is analytically assessed. Theoretical predictions are compared with simulation results, obtained by means of ELEctron Generation ANd Tracking (ELEGANT) code, in the case study of the gamma beam system (GBS) at the extreme light infrastructure—nuclear physics (ELI-NP). In particular, the relative error affecting the bunch length measurement, for bunches characterized by both energy chirp and fixed correlation coefficients between longitudinal particle positions and the vertical plane, is reported. Moreover, the relative error versus the correlation coefficients is shown for fixed RFD phase 0 rad and π rad. The relationship between relative error and correlations factors can help the decision of using the bunch length measurement technique with one or two vertical spot size measurements in order to cancel the correlations contribution. In the case of the GBS electron LINAC, the misalignment of one of the quadrupoles before the RFD between −2 mm and 2 mm leads to a relative error less than 5%. The misalignment of the first C-band accelerating section between −2 mm and 2 mm could lead to a relative error up to 10%.
2018
correlations between particle longitudinal positions and vertical plane; electron bunch length; ELI-NP; gamma beam system; LINAC; RF deflector; Instrumentation; Applied Mathematics
01 Pubblicazione su rivista::01a Articolo in rivista
Effects of correlations between particle longitudinal positions and transverse plane on bunch length measurement: A case study on GBS electron LINAC at ELI-NP / Sabato, L.; Arpaia, P.; Cianchi, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Variola, A.. - In: MEASUREMENT SCIENCE & TECHNOLOGY. - ISSN 0957-0233. - ELETTRONICO. - 29:2(2018), p. 024005. [10.1088/1361-6501/aaa281]
File allegati a questo prodotto
File Dimensione Formato  
Sabato_2018_Meas._Sci._Technol._29_024005.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 702.82 kB
Formato Adobe PDF
702.82 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1081811
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact