OBJECTIVES: This study sought to summarize the evidence on stress myocardial perfusion imaging (MPI) using cadmium-zinc-telluride (CZT) technology for the diagnosis of obstructive coronary artery disease (CAD). The CZT cameras are newly introduced, and comparative data with the conventional Anger technology (Anger-MPI) are lacking. BACKGROUND: The diagnostic accuracy of Anger-MPI for detection of angiographically significant CAD is well established; however, less evidence is available on the diagnostic accuracy of CZT-MPI. METHODS: Clinical studies comparing CZT-MPI and invasive coronary angiography were systematically searched and abstracted. Calculations of diagnostic accuracy, including sensitivity, specificity, likelihood ratios, and diagnostic odds ratio, were obtained with fixed and random effects, reporting point estimates and 95% confidence intervals. RESULTS: Based on our search, a total of 16 studies (N = 2,092) were included. The sensitivity of CZT-MPI was 0.84 (95% confidence interval [CI]: 0.78 to 0.89), whereas the specificity of 0.69 (95% CI: 0.62 to 0.76) was significantly reduced. The positive likelihood ratio was 2.73 (95% CI: 2.21 to 3.39), the negative likelihood ratio was 0.24 (95% CI: 0.17 to 0.31), and the diagnostic odds ratio was 11.93 (95% CI: 7.84 to 17.42). At subgroup and meta-regression analyses, the diagnostic accuracy between D-SPECT and Discovery cameras was similar (p = 0.711) and not impacted upon by smaller sample size studies (p = 0.573). CONCLUSIONS: CZT-MPI has satisfactory sensitivity for angiographically significant CAD, but its suboptimal specificity warrants further development and research.

Diagnostic accuracy of myocardial perfusion imaging with czt technology. Systemic review and meta-analysis of comparison with invasive coronary angiography / Nudi, Francesco; Iskandrian, Ami E.; Schillaci, Orazio; Peruzzi, Mariangela; Frati, Giacomo; Biondi-Zoccai, Giuseppe. - In: JACC. CARDIOVASCULAR IMAGING. - ISSN 1936-878X. - 10:7(2017), pp. 787-794. [10.1016/j.jcmg.2016.10.023]

Diagnostic accuracy of myocardial perfusion imaging with czt technology. Systemic review and meta-analysis of comparison with invasive coronary angiography

Peruzzi, Mariangela;Frati, Giacomo;Biondi-Zoccai, Giuseppe
2017

Abstract

OBJECTIVES: This study sought to summarize the evidence on stress myocardial perfusion imaging (MPI) using cadmium-zinc-telluride (CZT) technology for the diagnosis of obstructive coronary artery disease (CAD). The CZT cameras are newly introduced, and comparative data with the conventional Anger technology (Anger-MPI) are lacking. BACKGROUND: The diagnostic accuracy of Anger-MPI for detection of angiographically significant CAD is well established; however, less evidence is available on the diagnostic accuracy of CZT-MPI. METHODS: Clinical studies comparing CZT-MPI and invasive coronary angiography were systematically searched and abstracted. Calculations of diagnostic accuracy, including sensitivity, specificity, likelihood ratios, and diagnostic odds ratio, were obtained with fixed and random effects, reporting point estimates and 95% confidence intervals. RESULTS: Based on our search, a total of 16 studies (N = 2,092) were included. The sensitivity of CZT-MPI was 0.84 (95% confidence interval [CI]: 0.78 to 0.89), whereas the specificity of 0.69 (95% CI: 0.62 to 0.76) was significantly reduced. The positive likelihood ratio was 2.73 (95% CI: 2.21 to 3.39), the negative likelihood ratio was 0.24 (95% CI: 0.17 to 0.31), and the diagnostic odds ratio was 11.93 (95% CI: 7.84 to 17.42). At subgroup and meta-regression analyses, the diagnostic accuracy between D-SPECT and Discovery cameras was similar (p = 0.711) and not impacted upon by smaller sample size studies (p = 0.573). CONCLUSIONS: CZT-MPI has satisfactory sensitivity for angiographically significant CAD, but its suboptimal specificity warrants further development and research.
2017
cadmium-zinc-telluride; coronary artery disease; myocardial ischemia; myocardial perfusion imaging; single-photon emission computed tomography; radiology, nuclear medicine and imaging; cardiology and cardiovascular medicine
01 Pubblicazione su rivista::01a Articolo in rivista
Diagnostic accuracy of myocardial perfusion imaging with czt technology. Systemic review and meta-analysis of comparison with invasive coronary angiography / Nudi, Francesco; Iskandrian, Ami E.; Schillaci, Orazio; Peruzzi, Mariangela; Frati, Giacomo; Biondi-Zoccai, Giuseppe. - In: JACC. CARDIOVASCULAR IMAGING. - ISSN 1936-878X. - 10:7(2017), pp. 787-794. [10.1016/j.jcmg.2016.10.023]
File allegati a questo prodotto
File Dimensione Formato  
Nudi_Diagnostic-accuracy_2017.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 423.89 kB
Formato Adobe PDF
423.89 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1079700
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 79
  • ???jsp.display-item.citation.isi??? 67
social impact