We report the case of a 71-year-old man with creatinine clearance of 41 mL/min and acute anterior ST-segment elevation who underwent urgent coronary artery bypass grafting. A continuous intraoperative veno-arterial hemofiltration with high volumes of exchange (35 mL/kg/h) was used in a series for a miniaturized extracorporeal bypass system to minimize the inflammatory response and to protect the kidneys of this patient who had preoperative renal dysfunction. The patient had an uneventful postoperative recovery.
Intraoperative veno-arterial hemofiltration during miniaturized extracorporeal bypass / Fabio, Capuano; Roberto, Bianchini; Massimo, Goracci; Antonino, Roscitano; Remo, Luciani; Caterina, Simon; Leda, Giusti; Sinatra, Riccardo. - In: ANNALS OF THORACIC SURGERY. - ISSN 0003-4975. - 83:6(2007), pp. 2215-2216. [10.1016/j.athoracsur.2006.12.002]
Intraoperative veno-arterial hemofiltration during miniaturized extracorporeal bypass
SINATRA, Riccardo
2007
Abstract
We report the case of a 71-year-old man with creatinine clearance of 41 mL/min and acute anterior ST-segment elevation who underwent urgent coronary artery bypass grafting. A continuous intraoperative veno-arterial hemofiltration with high volumes of exchange (35 mL/kg/h) was used in a series for a miniaturized extracorporeal bypass system to minimize the inflammatory response and to protect the kidneys of this patient who had preoperative renal dysfunction. The patient had an uneventful postoperative recovery.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.