The RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the
pseudorapidity region 1.6<|η|<2.4. An ongoing project aims at covering the region of the muon
endcaps with large-area triple-GEM detectors whose features are suited to enhance muon tracking
and preserve triggering capabilities for the CMS detector upgrade. The design and assembling
of small (10 cm × 10 cm) and full-size trapezoidal (1 m × 0.5 m) triple-GEM prototypes will be
described. The prototypes have been tested with soft x-rays and with a pion/muon test beam
at the CERN SPS. Results from measurements with different experimental set-up on detector
resolution and efficiency as well as timing performance will be reported. Preliminary simulation
results will be discussed, related to studies on performance variations of the expected muon tracks
reconstruction and trigger performance for different upgraded muon system scenarios.
Performance studies of large-area triple-GEM prototypes for future upgrades of the CMS forward muon system / Tupputi, Salvatore A.; Abbrescia, M.; Colaleo, A.; De Robertis, G.; Loddo, F.; Maggi, M.; Nuzzo, S.; Ban, Y.; Cai, J.; Teng, H.; Mohapatra, A.; Moulik, T.; Gutierrez, A.; Karchin, P. E.; Benussi, L.; Bianco, S.; Colafranceschi, S.; Piccolo, D.; Raffone, G.; Saviano, G.; Abbaneo, D.; Aspell, P.; Bally, S.; Berzano, U.; Bos, J.; Chatelain, J. P.; Christiansen, J.; Conde Garcia, A.; David, E.; De Oliveira, R.; Duarte Pinto, S.; Ferry, S.; Formenti, F.; Marchioro, A.; Postema, H.; Rodrigues, A.; Ropelewski, L.; Sharma, A.; Smilkjovic, N.; Zientek, M.; Marinov, A.; Tytgat, M.; Zaganidis, N.; Gnanvo, K.; Hohlmann, M.; Staib, M. J.; Magazzu, G.; Olivieri, E.; Turini, N.; Bunkowski, K.. - ELETTRONICO. - 2011-:(2011), pp. 1-4. ( 21st International Europhysics Conference on High Energy Physics, EPS-HEP 2011 Grenoble, RhoneAlpes; France 21 July 2011 through 27 July 2011).
Performance studies of large-area triple-GEM prototypes for future upgrades of the CMS forward muon system
The RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the
pseudorapidity region 1.6<|η|<2.4. An ongoing project aims at covering the region of the muon
endcaps with large-area triple-GEM detectors whose features are suited to enhance muon tracking
and preserve triggering capabilities for the CMS detector upgrade. The design and assembling
of small (10 cm × 10 cm) and full-size trapezoidal (1 m × 0.5 m) triple-GEM prototypes will be
described. The prototypes have been tested with soft x-rays and with a pion/muon test beam
at the CERN SPS. Results from measurements with different experimental set-up on detector
resolution and efficiency as well as timing performance will be reported. Preliminary simulation
results will be discussed, related to studies on performance variations of the expected muon tracks
reconstruction and trigger performance for different upgraded muon system scenarios.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1066536
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
1
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.