Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
In the prospect of an upgrade of the CMS Experiment, an international collaboration is performing feasibility studies on employing large-area triple-GEM detectors for the high-η region (1.6-2.4) of the CMS Endcap, which is currently not instrumented. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in this region. A detailed review of the development and characterization of small and full-size (1m x 0.5m) prototypes will be presented. These full-size GEM foils are produced using a novel single-mask etching technique developed at CERN. In addition, we discuss the performance of a full-size trapezoidal triple-GEM detector in a strong magnetic field during a dedicated beam test campaign to address CMS requirements on the detectors.
Construction and performance of full scale gem prototypes for future upgrades of the CMS forward muon system / Abbrescia, M.; Colaleo, A.; De Robertis, G.; Loddo, F.; Maggi, M.; Nuzzo, S.; Thpputi, S. A.; Ban, Y.; Cai, J.; Teng, H.; Mohapatra, A.; Moulik, T.; Gutierrez, A.; Karchin, P. E.; Benussi, L.; Bianco, S.; Colafranceschi, S.; Piccolo, D.; Raffone, G.; Saviano, G.; Abbaneo, D.; Aspell, P.; Bally, S.; Bos, J.; Chatelain, J. P.; Christiansen, J.; Garcia, A. Conde; David, E.; De Oliveira, R.; Pinto, S. Duarte; Ferry, S.; Formenti, F.; Marchioro, A.; Postema, H.; Rodrigues, A.; Ropelewski, L.; Sharma, A.; Smilkjovic, N.; Zientek, M.; Marinov, A.; Tytga. t, M.; Zaganidis, N.; Gnanvo, K.; Hohlmann, M.; Staib, M. J.; Magazzu, G.; Olivieri, E.; Turini, N.; Btmkowski, K.; Fruboes, T.. - ELETTRONICO. - (2012), pp. 554-558. (Intervento presentato al convegno 13th International Conference on Advanced Technology and Particle Physics, ICATPP 2011 tenutosi a Como, ita nel 2011) [10.1142/9789814405072_0081].
Construction and performance of full scale gem prototypes for future upgrades of the CMS forward muon system
Abbrescia, M.;Colaleo, A.;De Robertis, G.;Loddo, F.;Maggi, M.;Nuzzo, S.;Thpputi, S. A.;Ban, Y.;Cai, J.;Teng, H.;Mohapatra, A.;Moulik, T.;Gutierrez, A.;Karchin, P. E.;Benussi, L.;Bianco, S.;Colafranceschi, S.;Piccolo, D.;Raffone, G.;Saviano, G.;Abbaneo, D.;Aspell, P.;Bally, S.;Bos, J.;Chatelain, J. P.;Christiansen, J.;Garcia, A. Conde;David, E.;De Oliveira, R.;Pinto, S. Duarte;Ferry, S.;Formenti, F.;Marchioro, A.;Postema, H.;Rodrigues, A.;Ropelewski, L.;Sharma, A.;Smilkjovic, N.;Zientek, M.;Marinov, A.;Tytga. t, M.;Zaganidis, N.;Gnanvo, K.;Hohlmann, M.;Staib, M. J.;Magazzu, G.;Olivieri, E.;Turini, N.;Btmkowski, K.;Fruboes, T.
2012
Abstract
In the prospect of an upgrade of the CMS Experiment, an international collaboration is performing feasibility studies on employing large-area triple-GEM detectors for the high-η region (1.6-2.4) of the CMS Endcap, which is currently not instrumented. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in this region. A detailed review of the development and characterization of small and full-size (1m x 0.5m) prototypes will be presented. These full-size GEM foils are produced using a novel single-mask etching technique developed at CERN. In addition, we discuss the performance of a full-size trapezoidal triple-GEM detector in a strong magnetic field during a dedicated beam test campaign to address CMS requirements on the detectors.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1066507
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.