For the High-Luminosity LHC (HL-LHC) phase the CMS GEM Collaboration is planning to install new large-size (990×220-455mm2) triple-GEM detectors, equipped with a new readout system, in the forward region of the muon system (1.5<; |η| <;2.2) of the CMS detector. Combining triggering and tracking functionalities the new triple-foil Gas Electron Multiplier (GEM) chambers will improve both the performance of the CMS muon trigger and the muon reconstruction/identification in CMS experiment. The addition of triple-GEM chambers to the forward region of the CMS muon system will add a necessary layer of redundancy. Starting from 2009 the CMS GEM Collaboration has built several small and full-size prototypes with different geometries, keeping improving the assembly techniques. All these prototypes have been tested in laboratories as well as with beam tests at the CERN Super Proton Synchrotron (SPS) and at Fermi National Accelerator Laboratory. In this contribution we will report on the status of the CMS upgrade project with triple-GEM chambers and its impact on the CMS performance as well as the hardware architectures and expected capability of the CMS GEM readout system.

Status report on the CMS forward muon upgrade with large-size triple-GEM detectors / Abbaneo, D.; Abbas, M.; Abbrescia, M.; Abdelalim, A. A.; Abi Akl, M.; Ahmed, W.; Ahmed, W.; Altieri, P.; Aly, R.; Asawatangtrakuldee, C.; Ashfaq, A.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barria, P.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F. R.; Celik, A.; Choi, M.; Choi, K.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Dabrowski, M. M.; De Lentdecker, G.; De Oliveira, R.; De Robertis, G.; Dildick, S.; Dorney, B.; Elmetenawee, W.; Fabrice, G.; Ferrini, M.; Ferry, S.; Giacomelli, P.; Gilmore, J.; Guiducci, L.; Gutierrez, A.; Hadjiiska, R. M.; Hassan, A.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Jeng, Y. G.; Kamon, T.; Karchin, P. E.; Kim, H. S.; Krutelyov, S.; Kumar, A.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Maerschalk, T.; Magazzu, G.; Maggi, M.; Maghrbi, Y.; Magnani, A.; Majumdar, N.; Mal, P. K.; Mandal, K.; Marchioro, A.; Marinov, A.; Merlin, J. A.; Mohanty, A. K.; Mohapatra, A.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L. M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Phipps, M.; Piccolo, D.; Postema, H.; Pugliese, G.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ramkrishna, S.; Ranieri, A.; Riccardi, C.; Rodrigues, A.; Ropelewski, L.; Roychowdhury, S.; Ryu, M. S.; Ryu, G.; Safonov, A.; Sakharov, A.; Salva, S.; Saviano, G.; Sharma, A.; Swain, S. K.; Talvitie, J. P.; Tamma, C.; Tatarinov, A.; Turini, N.; Tuuva, T.; Twigger, J.; Tytgat, M.; Vai, I.; Van Stenis, M.; Venditi, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.. - ELETTRONICO. - (2016), pp. 1-8. (Intervento presentato al convegno IEEE Nuclear science symposium and medical imaging conference, NSS/MIC 2014 tenutosi a Seattle; USA nel 2014) [10.1109/NSSMIC.2014.7431236].

Status report on the CMS forward muon upgrade with large-size triple-GEM detectors

Ferrini, M.;Muhammad, S.;Saviano, G.;
2016

Abstract

For the High-Luminosity LHC (HL-LHC) phase the CMS GEM Collaboration is planning to install new large-size (990×220-455mm2) triple-GEM detectors, equipped with a new readout system, in the forward region of the muon system (1.5<; |η| <;2.2) of the CMS detector. Combining triggering and tracking functionalities the new triple-foil Gas Electron Multiplier (GEM) chambers will improve both the performance of the CMS muon trigger and the muon reconstruction/identification in CMS experiment. The addition of triple-GEM chambers to the forward region of the CMS muon system will add a necessary layer of redundancy. Starting from 2009 the CMS GEM Collaboration has built several small and full-size prototypes with different geometries, keeping improving the assembly techniques. All these prototypes have been tested in laboratories as well as with beam tests at the CERN Super Proton Synchrotron (SPS) and at Fermi National Accelerator Laboratory. In this contribution we will report on the status of the CMS upgrade project with triple-GEM chambers and its impact on the CMS performance as well as the hardware architectures and expected capability of the CMS GEM readout system.
2016
IEEE Nuclear science symposium and medical imaging conference, NSS/MIC 2014
nuclear and high energy physics; radiology, nuclear medicine and imaging
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Status report on the CMS forward muon upgrade with large-size triple-GEM detectors / Abbaneo, D.; Abbas, M.; Abbrescia, M.; Abdelalim, A. A.; Abi Akl, M.; Ahmed, W.; Ahmed, W.; Altieri, P.; Aly, R.; Asawatangtrakuldee, C.; Ashfaq, A.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barria, P.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F. R.; Celik, A.; Choi, M.; Choi, K.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Dabrowski, M. M.; De Lentdecker, G.; De Oliveira, R.; De Robertis, G.; Dildick, S.; Dorney, B.; Elmetenawee, W.; Fabrice, G.; Ferrini, M.; Ferry, S.; Giacomelli, P.; Gilmore, J.; Guiducci, L.; Gutierrez, A.; Hadjiiska, R. M.; Hassan, A.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Jeng, Y. G.; Kamon, T.; Karchin, P. E.; Kim, H. S.; Krutelyov, S.; Kumar, A.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Maerschalk, T.; Magazzu, G.; Maggi, M.; Maghrbi, Y.; Magnani, A.; Majumdar, N.; Mal, P. K.; Mandal, K.; Marchioro, A.; Marinov, A.; Merlin, J. A.; Mohanty, A. K.; Mohapatra, A.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L. M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Phipps, M.; Piccolo, D.; Postema, H.; Pugliese, G.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ramkrishna, S.; Ranieri, A.; Riccardi, C.; Rodrigues, A.; Ropelewski, L.; Roychowdhury, S.; Ryu, M. S.; Ryu, G.; Safonov, A.; Sakharov, A.; Salva, S.; Saviano, G.; Sharma, A.; Swain, S. K.; Talvitie, J. P.; Tamma, C.; Tatarinov, A.; Turini, N.; Tuuva, T.; Twigger, J.; Tytgat, M.; Vai, I.; Van Stenis, M.; Venditi, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.. - ELETTRONICO. - (2016), pp. 1-8. (Intervento presentato al convegno IEEE Nuclear science symposium and medical imaging conference, NSS/MIC 2014 tenutosi a Seattle; USA nel 2014) [10.1109/NSSMIC.2014.7431236].
File allegati a questo prodotto
File Dimensione Formato  
Abbaneo_Status-report-CMS_2016.pdf

solo gestori archivio

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1066439
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact