Background: This study was conducted to assess the accuracy of harmonic imaging 2D-transthoracic echocardiography (2D-TTE) segmental analysis compared to surgical findings, in degenerative mitral regurgitation (MR). Methods: Seventy-seven consecutive patients with severe degenerative MR were prospectively enrolled. Preoperative 2D-TTE with precise localization of prolapsing or flailing scallops/segments was performed. All patients underwent mitral valve surgical repair. Surgical reports (SR), including valve description, were used as references for comparisons. A postoperative control 2D-TTE was performed. Results: Out of 462 scallops/segments studied, surgical inspection identified 102 prolapses or flails (22%), 92 of which had previously been detected by 2D-TTE (90.2% sensitivity, 100% specificity). Agreement between preoperative 2D-TTE segmental analysis and SR was 97.8% (k = 0.93; p < 0.0001). Sixty-nine out of 77 2D-TTE reports were completely concordant with SR (89.6% diagnostic accuracy). None of the 8 non-concordant 2D-TTE reports were in complete disagreement with SR. P2 scallop was always involved in posterior leaflet prolapse or flail and was described correctly by 2D-TTE in 68 out of 69 patients (98,7% agreement, k = 0,93; 98.5% sensitivity). The anterior leaflet was involved in 14 patients (18%); A2 segment was involved in all of those cases and was correctly detected by 2D-TTE in 13 (98,7% agreement, k = 0,95; 92,8% sensitivity). Antero-lateral and postero-medial para-commissural prolapse or flail had a lower prevalence (14% and 10% respectively), with 2D-TTE sensitivity respectively of 64% and 50%. Conclusions: 2D-TTE, performed by an experienced echo-lab, has very good diagnostic accuracy in localizing the scallops/segments involved in degenerative MR, particularly for the middle ones (P2-A2), which represent almost the totality of prolapses. More invasive, time consuming and expensive exams should be reserved to selected cases.

Preoperative scallop-by-scallop assessment of mitral prolapse using 2D-transthoracic echocardiography / Giovanni, Minardi; Pino, Pg; Carla, Manzara; Giovanni, Pulignano; Giulio, Stefanini; Stefania, Leonetti; Andrea, Madeo; Gaudio, Carlo; Francesco, Musumeci; Viceconte, GIUSEPPE NICOLA. - In: CARDIOVASCULAR ULTRASOUND. - ISSN 1476-7120. - ELETTRONICO. - 8:1(2010), pp. 1-9. [10.1186/1476-7120-8-1]

Preoperative scallop-by-scallop assessment of mitral prolapse using 2D-transthoracic echocardiography

GAUDIO, Carlo;VICECONTE, GIUSEPPE NICOLA
2010

Abstract

Background: This study was conducted to assess the accuracy of harmonic imaging 2D-transthoracic echocardiography (2D-TTE) segmental analysis compared to surgical findings, in degenerative mitral regurgitation (MR). Methods: Seventy-seven consecutive patients with severe degenerative MR were prospectively enrolled. Preoperative 2D-TTE with precise localization of prolapsing or flailing scallops/segments was performed. All patients underwent mitral valve surgical repair. Surgical reports (SR), including valve description, were used as references for comparisons. A postoperative control 2D-TTE was performed. Results: Out of 462 scallops/segments studied, surgical inspection identified 102 prolapses or flails (22%), 92 of which had previously been detected by 2D-TTE (90.2% sensitivity, 100% specificity). Agreement between preoperative 2D-TTE segmental analysis and SR was 97.8% (k = 0.93; p < 0.0001). Sixty-nine out of 77 2D-TTE reports were completely concordant with SR (89.6% diagnostic accuracy). None of the 8 non-concordant 2D-TTE reports were in complete disagreement with SR. P2 scallop was always involved in posterior leaflet prolapse or flail and was described correctly by 2D-TTE in 68 out of 69 patients (98,7% agreement, k = 0,93; 98.5% sensitivity). The anterior leaflet was involved in 14 patients (18%); A2 segment was involved in all of those cases and was correctly detected by 2D-TTE in 13 (98,7% agreement, k = 0,95; 92,8% sensitivity). Antero-lateral and postero-medial para-commissural prolapse or flail had a lower prevalence (14% and 10% respectively), with 2D-TTE sensitivity respectively of 64% and 50%. Conclusions: 2D-TTE, performed by an experienced echo-lab, has very good diagnostic accuracy in localizing the scallops/segments involved in degenerative MR, particularly for the middle ones (P2-A2), which represent almost the totality of prolapses. More invasive, time consuming and expensive exams should be reserved to selected cases.
2010
Ultrtasuoni
01 Pubblicazione su rivista::01a Articolo in rivista
Preoperative scallop-by-scallop assessment of mitral prolapse using 2D-transthoracic echocardiography / Giovanni, Minardi; Pino, Pg; Carla, Manzara; Giovanni, Pulignano; Giulio, Stefanini; Stefania, Leonetti; Andrea, Madeo; Gaudio, Carlo; Francesco, Musumeci; Viceconte, GIUSEPPE NICOLA. - In: CARDIOVASCULAR ULTRASOUND. - ISSN 1476-7120. - ELETTRONICO. - 8:1(2010), pp. 1-9. [10.1186/1476-7120-8-1]
File allegati a questo prodotto
File Dimensione Formato  
Preoperative scallop-by-scallop assessment of mitral prolapse using.pdf

accesso aperto

Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 594.56 kB
Formato Adobe PDF
594.56 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/106600
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact