A new method of autofluorescence quantification: software module autofluorescence quantitative analysis. Age related macular disease (AMD) is now the leading cause of severe visual loss in all industrialized countries. It may be speculated that changes seen in FAF imaging on the RPE cell level precede the occurrence of visible lesions as the disease progresses. There is no an universally accepted standard method to quantification FAF. It should be remembered that AF measurements are relative and subject to degradation by the lens, rather than absolute values obtained spectroscopically. To make quantitative assessment of abnormal AF we planed a new method based on the quantification of grey variations between two images of AF, recorded in different period, in the same patients. Key words: autofluorescence quantification, age-related macular degeneration

Una nuova tecnica per la misurazione dell’autofluorescenza del fondo oculare: modulo software per l’analisi quantitativa dell’autofluorescenza del fondo oculare / Giustolisi, Rosalia; Fantozzi, N; BALACCO GABRIELI, C.. - In: BOLLETTINO DI OCULISTICA. - ISSN 0006-677X. - STAMPA. - n. 2:(2007), pp. 159-165.

Una nuova tecnica per la misurazione dell’autofluorescenza del fondo oculare: modulo software per l’analisi quantitativa dell’autofluorescenza del fondo oculare

GIUSTOLISI, Rosalia;
2007

Abstract

A new method of autofluorescence quantification: software module autofluorescence quantitative analysis. Age related macular disease (AMD) is now the leading cause of severe visual loss in all industrialized countries. It may be speculated that changes seen in FAF imaging on the RPE cell level precede the occurrence of visible lesions as the disease progresses. There is no an universally accepted standard method to quantification FAF. It should be remembered that AF measurements are relative and subject to degradation by the lens, rather than absolute values obtained spectroscopically. To make quantitative assessment of abnormal AF we planed a new method based on the quantification of grey variations between two images of AF, recorded in different period, in the same patients. Key words: autofluorescence quantification, age-related macular degeneration
2007
01 Pubblicazione su rivista::01a Articolo in rivista
Una nuova tecnica per la misurazione dell’autofluorescenza del fondo oculare: modulo software per l’analisi quantitativa dell’autofluorescenza del fondo oculare / Giustolisi, Rosalia; Fantozzi, N; BALACCO GABRIELI, C.. - In: BOLLETTINO DI OCULISTICA. - ISSN 0006-677X. - STAMPA. - n. 2:(2007), pp. 159-165.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/105190
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact