Background Segond’s fracture is a well-recognised radiological sign of an anterior cruciate ligament (ACL) tear. While previous studies evaluated the role of the anterolateral ligament (ALL) and complex injuries on rotational stability of the knee, there are no studies on the biomechanical effect of Segond’s fracture in an ACL deficient knee. The aim of this study was to evaluate the effect of a Segond’s fracture on knee rotation stability as evaluated by a navigation system in an ACL deficient knee. Materials and methods Three different conditions were tested on seven knee specimens: intact knee, ACL deficient knee and ACL deficient knee with Segond’s fracture. Static and dynamic measurements of anterior tibial translation (ATT) and axial tibial rotation (ATR) were recorded by the navigation system (2.2 OrthoPilot ACL navigation system B. Braun Aesculap, Tuttlingen, Germany). Results Static measurements at 30 showed that the mean ATT at 30 of knee flexion was 5.1 ± 2.7 mm in the ACL intact condition, 14.3 ± 3.1 mm after ACL cut (P = 0.005), and 15.2 ± 3.6 mm after Segond’s fracture (P = 0.08). The mean ATR at 30 of knee flexion was 20.7 ± 4.8 in the ACL intact condition, 26.9 ± 4.1 in the ACL deficient knee (P[0.05) and 30.9 ± 3.8 after Segond’s fracture (P = 0.005). Dynamic measurements during the pivot-shift showed that the mean ATT was 7.2 ± 2.7 mm in the intact knee, 9.1 ± 3.3 mm in the ACL deficient knee(P = 0.04) and 9.7 ± 4.3 mm in the ACL deficient knee with Segond’s fracture (P = 0.07). The mean ATR was 9.6 ± 1.8 in the intact knee, 12.3 ± 2.3 in the ACL deficient knee (P[0.05) and 19.1 ± 3.1 in the ACL deficient knee with Segond’s lesion (P = 0.016). Conclusion An isolated lesion of the ACL only affects ATT during static and dynamic measurements, while the addition of Segond’s fracture has a significant effect on ATR in both static and dynamic execution of the pivot-shift test, as evaluated with the aid of navigation.

Segond's fracture: a biomechanical cadaveric study using navigation / Monaco, E.; Mazza, Daniele; Redler, A.; Lupariello, D.; Lanzetti, R.; Guzzini, M.; Ferretti, A.. - In: JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY. - ISSN 1590-9921. - 18:4(2017), pp. 1-6. [10.1007/s10195-017-0460-0]

Segond's fracture: a biomechanical cadaveric study using navigation

Monaco, E.;Mazza, Daniele;Redler, A.;Lupariello, D.;Lanzetti, R.;Guzzini, M.;Ferretti, A.
2017

Abstract

Background Segond’s fracture is a well-recognised radiological sign of an anterior cruciate ligament (ACL) tear. While previous studies evaluated the role of the anterolateral ligament (ALL) and complex injuries on rotational stability of the knee, there are no studies on the biomechanical effect of Segond’s fracture in an ACL deficient knee. The aim of this study was to evaluate the effect of a Segond’s fracture on knee rotation stability as evaluated by a navigation system in an ACL deficient knee. Materials and methods Three different conditions were tested on seven knee specimens: intact knee, ACL deficient knee and ACL deficient knee with Segond’s fracture. Static and dynamic measurements of anterior tibial translation (ATT) and axial tibial rotation (ATR) were recorded by the navigation system (2.2 OrthoPilot ACL navigation system B. Braun Aesculap, Tuttlingen, Germany). Results Static measurements at 30 showed that the mean ATT at 30 of knee flexion was 5.1 ± 2.7 mm in the ACL intact condition, 14.3 ± 3.1 mm after ACL cut (P = 0.005), and 15.2 ± 3.6 mm after Segond’s fracture (P = 0.08). The mean ATR at 30 of knee flexion was 20.7 ± 4.8 in the ACL intact condition, 26.9 ± 4.1 in the ACL deficient knee (P[0.05) and 30.9 ± 3.8 after Segond’s fracture (P = 0.005). Dynamic measurements during the pivot-shift showed that the mean ATT was 7.2 ± 2.7 mm in the intact knee, 9.1 ± 3.3 mm in the ACL deficient knee(P = 0.04) and 9.7 ± 4.3 mm in the ACL deficient knee with Segond’s fracture (P = 0.07). The mean ATR was 9.6 ± 1.8 in the intact knee, 12.3 ± 2.3 in the ACL deficient knee (P[0.05) and 19.1 ± 3.1 in the ACL deficient knee with Segond’s lesion (P = 0.016). Conclusion An isolated lesion of the ACL only affects ATT during static and dynamic measurements, while the addition of Segond’s fracture has a significant effect on ATR in both static and dynamic execution of the pivot-shift test, as evaluated with the aid of navigation.
2017
anterior cruciate ligament; navigation; pivot-shift; segond's fracture; surgery; orthopedics and sports medicine
01 Pubblicazione su rivista::01a Articolo in rivista
Segond's fracture: a biomechanical cadaveric study using navigation / Monaco, E.; Mazza, Daniele; Redler, A.; Lupariello, D.; Lanzetti, R.; Guzzini, M.; Ferretti, A.. - In: JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY. - ISSN 1590-9921. - 18:4(2017), pp. 1-6. [10.1007/s10195-017-0460-0]
File allegati a questo prodotto
File Dimensione Formato  
Monaco_Segond’s-fracture_2017.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 587 kB
Formato Adobe PDF
587 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1048763
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 9
social impact