Objective: Hypoxic-ischemic encephalopathy (HIE) is one of the major causes of perinatal mortality and morbidity. To date, there are no reliable methods to detect which infants will develop brain damage after asphyxia insult. Design and Setting: Prospective study conducted in three tertiary departments of neonatology from December 1999 to July 2002. Participants: A total of 44 infants with perinatal asphyxia and 68 control infants. Intervention: Routine laboratory variables, neurologic patterns, ultrasound imaging, and urine concentrations of S100B protein were determined at nine time points. Main Outcome Measures: The concentrations of S100B protein in urine were measured using an immunoluminometric assay at first urination and 4, 8, 12, 16, 20, 24, 48, and 72 hrs after birth. The results were correlated with the presence or absence of hypoxic-ischemic encephalopathy. Routine laboratory parameters and neurologic patterns were assessed at the same time as urine sampling. Results: S10013 protein levels were significantly higher in samples collected at all monitoring time points from newborns with perinatal asphyxia with or without hypoxic-ischemic encephalopathy than in samples from normal infants (all p < .001). When asphyxiated infants were subdivided according to the presence of mild or absence of hypoxic-ischemic encephaloparthy (group A) and of moderate or severe hypoxic-ischemic encephaloparthy (group 13), S100B levels were significantly higher at all the predetermined monitoring time points in group B infants than group A or control infants (all p < .001). An S100B concentration cutoff of 0.41 mug/L at first urination had a sensitivity of 91.3% and a specificity of 94.6% for predicting the development of hypoxic-ischemic encephalopathy. The sensitivity and specificity of measurements obtained from 4 to 72 hrs after birth were up to 100% and 98.8%, respectively. Conclusions: Longitudinal S100B protein measurements in urine soon after birth are a useful tool to identify which asphyxiated infants are at risk of hypoxic-ischemic encephalopathy and its possible neurologic sequelae.

Urinary S100B protein measurements: A tool for the early identification of hypoxic-ischemic encephalopathy in asphyxiated full-term infants / Diego, Gazzolo; Marinoni, Emanuela; DI IORIO, Romolo; Matteo, Bruschettini; Maria, Kornacka; Mario, Lituania; Urszula, Majewska; Giovanni, Serra; Fabrizio, Michetti. - In: CRITICAL CARE MEDICINE. - ISSN 0090-3493. - STAMPA. - 32:1(2004), pp. 131-136. [10.1097/01.ccm.0000104116.91462.cd]

Urinary S100B protein measurements: A tool for the early identification of hypoxic-ischemic encephalopathy in asphyxiated full-term infants

MARINONI, EMANUELA;DI IORIO, Romolo;
2004

Abstract

Objective: Hypoxic-ischemic encephalopathy (HIE) is one of the major causes of perinatal mortality and morbidity. To date, there are no reliable methods to detect which infants will develop brain damage after asphyxia insult. Design and Setting: Prospective study conducted in three tertiary departments of neonatology from December 1999 to July 2002. Participants: A total of 44 infants with perinatal asphyxia and 68 control infants. Intervention: Routine laboratory variables, neurologic patterns, ultrasound imaging, and urine concentrations of S100B protein were determined at nine time points. Main Outcome Measures: The concentrations of S100B protein in urine were measured using an immunoluminometric assay at first urination and 4, 8, 12, 16, 20, 24, 48, and 72 hrs after birth. The results were correlated with the presence or absence of hypoxic-ischemic encephalopathy. Routine laboratory parameters and neurologic patterns were assessed at the same time as urine sampling. Results: S10013 protein levels were significantly higher in samples collected at all monitoring time points from newborns with perinatal asphyxia with or without hypoxic-ischemic encephalopathy than in samples from normal infants (all p < .001). When asphyxiated infants were subdivided according to the presence of mild or absence of hypoxic-ischemic encephaloparthy (group A) and of moderate or severe hypoxic-ischemic encephaloparthy (group 13), S100B levels were significantly higher at all the predetermined monitoring time points in group B infants than group A or control infants (all p < .001). An S100B concentration cutoff of 0.41 mug/L at first urination had a sensitivity of 91.3% and a specificity of 94.6% for predicting the development of hypoxic-ischemic encephalopathy. The sensitivity and specificity of measurements obtained from 4 to 72 hrs after birth were up to 100% and 98.8%, respectively. Conclusions: Longitudinal S100B protein measurements in urine soon after birth are a useful tool to identify which asphyxiated infants are at risk of hypoxic-ischemic encephalopathy and its possible neurologic sequelae.
2004
brain damage; hypoxic-ischemic encephalopathy; newborn; perinatal asphyxia; s100b protein
01 Pubblicazione su rivista::01a Articolo in rivista
Urinary S100B protein measurements: A tool for the early identification of hypoxic-ischemic encephalopathy in asphyxiated full-term infants / Diego, Gazzolo; Marinoni, Emanuela; DI IORIO, Romolo; Matteo, Bruschettini; Maria, Kornacka; Mario, Lituania; Urszula, Majewska; Giovanni, Serra; Fabrizio, Michetti. - In: CRITICAL CARE MEDICINE. - ISSN 0090-3493. - STAMPA. - 32:1(2004), pp. 131-136. [10.1097/01.ccm.0000104116.91462.cd]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/103702
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 75
  • ???jsp.display-item.citation.isi??? 66
social impact