BACKGROUND: Several strategies have been envisioned to reduce the risk of contrast-induced nephropathy, but the most modifiable approach for a treating physician is to minimize contrast administration. To date, there is no report on the use of Osprey Medical's new-generation DyeVert Plus system in coronary or peripheral applications. We aimed to appraise the role of the DyeVert Plus system inclusive of contrast reduction and real-time monitoring in a consecutive series of patients undergoing coronary or peripheral invasive procedures. METHODS: Baseline, procedural, and outcome details for patients undergoing coronary or peripheral invasive procedures were collected from our institutional database. We primarily focused on total and relative amount of contrast saved, as calculated and displayed by the DyeVert Plus system. RESULTS: The DyeVert Plus system was used in 10 patients. All procedures were successfully completed with adequate and high-quality angioscopic and angiographic images. No adverse events occurred up to discharge in any patients, with the notable exception of 1 case of asymptomatic and uneventful contrast-induced nephropathy. Average contrast volume was 79.9 ± 48.8 mL (95% confidence interval [CI], 53.2 to 109.4), thanks to an absolute saving of 55.8 ± 31.9 mL (95% CI, 39.1 to 76.7; P<.05) and a relative saving of 41.8 ± 7.3% (95% CI, 37.5 to 46.4; P<.05). Comparison of contrast volume estimates between DyeVert Plus vs manual measurements showed a minimal difference of 1.6 ± 1.9 mL (95% CI, 2.9 to 0.5; P<.05). CONCLUSION: Use of the new-generation DyeVert Plus system inclusive of contrast reduction and real-time monitoring is feasible in both coronary and peripheral applications while significantly reducing contrast volume.

Contrast minimization with the new-generation dyevert plus system for contrast reduction and real-time monitoring during coronary and peripheral procedures. First experience / Corcione, Nicola; BIONDI ZOCCAI, Giuseppe; Ferraro, Paolo; Messina, Stefano; Maresca, Gennaro; Avellino, Raffaella; Napolitano, Giovanni; Cavarretta, Elena; Giordano, Arturo. - In: JOURNAL OF INVASIVE CARDIOLOGY. - ISSN 1042-3931. - STAMPA. - 29:8(2017), pp. 259-262.

Contrast minimization with the new-generation dyevert plus system for contrast reduction and real-time monitoring during coronary and peripheral procedures. First experience

BIONDI ZOCCAI, GIUSEPPE
Conceptualization
;
CAVARRETTA, Elena
Writing – Review & Editing
;
2017

Abstract

BACKGROUND: Several strategies have been envisioned to reduce the risk of contrast-induced nephropathy, but the most modifiable approach for a treating physician is to minimize contrast administration. To date, there is no report on the use of Osprey Medical's new-generation DyeVert Plus system in coronary or peripheral applications. We aimed to appraise the role of the DyeVert Plus system inclusive of contrast reduction and real-time monitoring in a consecutive series of patients undergoing coronary or peripheral invasive procedures. METHODS: Baseline, procedural, and outcome details for patients undergoing coronary or peripheral invasive procedures were collected from our institutional database. We primarily focused on total and relative amount of contrast saved, as calculated and displayed by the DyeVert Plus system. RESULTS: The DyeVert Plus system was used in 10 patients. All procedures were successfully completed with adequate and high-quality angioscopic and angiographic images. No adverse events occurred up to discharge in any patients, with the notable exception of 1 case of asymptomatic and uneventful contrast-induced nephropathy. Average contrast volume was 79.9 ± 48.8 mL (95% confidence interval [CI], 53.2 to 109.4), thanks to an absolute saving of 55.8 ± 31.9 mL (95% CI, 39.1 to 76.7; P<.05) and a relative saving of 41.8 ± 7.3% (95% CI, 37.5 to 46.4; P<.05). Comparison of contrast volume estimates between DyeVert Plus vs manual measurements showed a minimal difference of 1.6 ± 1.9 mL (95% CI, 2.9 to 0.5; P<.05). CONCLUSION: Use of the new-generation DyeVert Plus system inclusive of contrast reduction and real-time monitoring is feasible in both coronary and peripheral applications while significantly reducing contrast volume.
2017
angiography; contrast; contrast minimization; contrast monitoring; contrast reduction; contrast-induced nephropathy; renal failure; Radiology, Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
01 Pubblicazione su rivista::01a Articolo in rivista
Contrast minimization with the new-generation dyevert plus system for contrast reduction and real-time monitoring during coronary and peripheral procedures. First experience / Corcione, Nicola; BIONDI ZOCCAI, Giuseppe; Ferraro, Paolo; Messina, Stefano; Maresca, Gennaro; Avellino, Raffaella; Napolitano, Giovanni; Cavarretta, Elena; Giordano, Arturo. - In: JOURNAL OF INVASIVE CARDIOLOGY. - ISSN 1042-3931. - STAMPA. - 29:8(2017), pp. 259-262.
File allegati a questo prodotto
File Dimensione Formato  
Corcione_Contrast-minimization_2017.pdf

solo gestori archivio

Note: articolo principale
Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1029420
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact