A QSTAR Pulsor quadrupole time-of-flight mass spectrometer was used for the determination of chlorophenols in surface water samples. The investigated compounds were: 2-chlorophenol; 4chloro-3-methylphenol; 2,4-dichlorophenol, 2,4,6-trichlorophenol and pentachlorophenol. Each analyte is listed by the US-EPA as a priority pollutant. Sample enrichment of water samples was achieved by a solid-phase extraction procedure, using a Waters Oasis HLB cartridges followed by LC-Tandem-MS. A narrow-bore 2.1-mm-i.d. reversed phase LC C-18 column operating with a mobile phase flow rate of 0.2 mL min(-1). was used to separate the analytes. The whole column effluent was diverted to the ion spray interface source. For the determination of the analytes the hybrid quadrupole time-of-flight spectrometer operated in product ion scan acquisition mode. Average recoveries from 2 L samples varied from 91 to 110% and relative standard deviations (RSD) were less than 10% for all samples. The limit of defection (signal-to-noise ratio=3) of the method for the phenols in drinking water samples is less than 10 ng L-1. In real environmental samples, levels of the selected analytes varied from non-detected" up to 0.5 mug L-1 for pentachlorophenol.

HYBRID QUADRUPOLE TIME-OF-FLIGHT FOR THE DETERMINATION OF CHLOROPHENOLS IN SURFACE WATER BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY / Marchese, Stefano; Gentili, Alessandra; Perret, Daniela; Sergi, Manuel; S., Notari. - In: CHROMATOGRAPHIA. - ISSN 0009-5893. - STAMPA. - 59:7-8(2004), pp. 411-417. [10.1365/s10337-004-0208-x]

HYBRID QUADRUPOLE TIME-OF-FLIGHT FOR THE DETERMINATION OF CHLOROPHENOLS IN SURFACE WATER BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY

MARCHESE, Stefano;GENTILI, Alessandra;PERRET, Daniela;SERGI, MANUEL;
2004

Abstract

A QSTAR Pulsor quadrupole time-of-flight mass spectrometer was used for the determination of chlorophenols in surface water samples. The investigated compounds were: 2-chlorophenol; 4chloro-3-methylphenol; 2,4-dichlorophenol, 2,4,6-trichlorophenol and pentachlorophenol. Each analyte is listed by the US-EPA as a priority pollutant. Sample enrichment of water samples was achieved by a solid-phase extraction procedure, using a Waters Oasis HLB cartridges followed by LC-Tandem-MS. A narrow-bore 2.1-mm-i.d. reversed phase LC C-18 column operating with a mobile phase flow rate of 0.2 mL min(-1). was used to separate the analytes. The whole column effluent was diverted to the ion spray interface source. For the determination of the analytes the hybrid quadrupole time-of-flight spectrometer operated in product ion scan acquisition mode. Average recoveries from 2 L samples varied from 91 to 110% and relative standard deviations (RSD) were less than 10% for all samples. The limit of defection (signal-to-noise ratio=3) of the method for the phenols in drinking water samples is less than 10 ng L-1. In real environmental samples, levels of the selected analytes varied from non-detected" up to 0.5 mug L-1 for pentachlorophenol.
2004
chlorophenols; lc-ms/ms; surface water analysis
01 Pubblicazione su rivista::01a Articolo in rivista
HYBRID QUADRUPOLE TIME-OF-FLIGHT FOR THE DETERMINATION OF CHLOROPHENOLS IN SURFACE WATER BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY / Marchese, Stefano; Gentili, Alessandra; Perret, Daniela; Sergi, Manuel; S., Notari. - In: CHROMATOGRAPHIA. - ISSN 0009-5893. - STAMPA. - 59:7-8(2004), pp. 411-417. [10.1365/s10337-004-0208-x]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/102052
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 20
social impact