INTRODUCTION: Despite increased operative time, minimally invasive cardiac surgery is associated with a lower morbidity than conventional aortic valve replacement (AVR). On the other hand, sutureless aortic bioprostheses have the potential of simplifying implantation, as it reduces the ischemic time. Our aim was to investigate the outcome of a sutureless AVR through a mini-sternotomy. MATERIALS AND METHODS: Since March 2010, a total of 262 patients affected by aortic valve stenosis underwent AVR with a sutureless bioprosthesis (Perceval, Sorin Group, Saluggia, Italy). Of these, 145 patients (mean age 77.8 ± 4.7 years, 80 women) underwent surgical AVR through a mini J-sternotomy. Clinical and echocardiographic data were evaluated. RESULTS: Patients received a size: S(12), M(49), L(67), or XL(17) prostheses, either as isolated (131) or combined procedures (14) including 2 redo patients who had undergone coronary artery bypass grafting via full sternotomy previously. Mean logistic EuroSCORE (I) was 9.9 ± 5.9%, and mean aortic cross-clamp time was 38 ± 12 minutes (35 ± 11 minutes in isolated procedures). Two conversions to full sternotomy were necessary because of bleeding. Thirty-day mortality was 2.1% (all noncardiac deaths); mean hospital stay was 11.6 ± 4.9 days. We recorded 11 pacemaker implantations (7.6%). At follow-up (23.5 ± 14.4 months), five patients were dead (three noncardiac and two cardiac deaths). At echocardiographic control, mean transprosthetic gradients were as follows: 12.8 ± 4.9, 12.5 ± 4.5, 11.8 ± 4.7 mm Hg, postoperatively at 6 months, 1 year, and 2 years, respectively. No paravalvular leaks were recorded. CONCLUSION: The sutureless bioprosthesis shows satisfactory clinical and hemodynamic results. Owing to its simple implantation technique, it represents a good support for minimally invasive access surgery via J-sternotomy.
Sutureless valve implantation via Mini J-Sternotomy: a single center experience with 2 years mean follow-up / Fischlein, Theodor; Pfeiffer, Steffen; Pollari, Francesco; Sirch, Joachim; Vogt, Ferdinand; Santarpino, Giuseppe. - In: THORACIC AND CARDIOVASCULAR SURGEON. - ISSN 0171-6425. - STAMPA. - 63:6(2015), pp. 467-471. [10.1055/s-0035-1554043]
Sutureless valve implantation via Mini J-Sternotomy: a single center experience with 2 years mean follow-up
Pollari, Francesco
Writing – Original Draft Preparation
;
2015
Abstract
INTRODUCTION: Despite increased operative time, minimally invasive cardiac surgery is associated with a lower morbidity than conventional aortic valve replacement (AVR). On the other hand, sutureless aortic bioprostheses have the potential of simplifying implantation, as it reduces the ischemic time. Our aim was to investigate the outcome of a sutureless AVR through a mini-sternotomy. MATERIALS AND METHODS: Since March 2010, a total of 262 patients affected by aortic valve stenosis underwent AVR with a sutureless bioprosthesis (Perceval, Sorin Group, Saluggia, Italy). Of these, 145 patients (mean age 77.8 ± 4.7 years, 80 women) underwent surgical AVR through a mini J-sternotomy. Clinical and echocardiographic data were evaluated. RESULTS: Patients received a size: S(12), M(49), L(67), or XL(17) prostheses, either as isolated (131) or combined procedures (14) including 2 redo patients who had undergone coronary artery bypass grafting via full sternotomy previously. Mean logistic EuroSCORE (I) was 9.9 ± 5.9%, and mean aortic cross-clamp time was 38 ± 12 minutes (35 ± 11 minutes in isolated procedures). Two conversions to full sternotomy were necessary because of bleeding. Thirty-day mortality was 2.1% (all noncardiac deaths); mean hospital stay was 11.6 ± 4.9 days. We recorded 11 pacemaker implantations (7.6%). At follow-up (23.5 ± 14.4 months), five patients were dead (three noncardiac and two cardiac deaths). At echocardiographic control, mean transprosthetic gradients were as follows: 12.8 ± 4.9, 12.5 ± 4.5, 11.8 ± 4.7 mm Hg, postoperatively at 6 months, 1 year, and 2 years, respectively. No paravalvular leaks were recorded. CONCLUSION: The sutureless bioprosthesis shows satisfactory clinical and hemodynamic results. Owing to its simple implantation technique, it represents a good support for minimally invasive access surgery via J-sternotomy.File | Dimensione | Formato | |
---|---|---|---|
Pollari_Sutureless-valve-implantation.pdf
solo gestori archivio
Note: Articolo principale
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
220.91 kB
Formato
Adobe PDF
|
220.91 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.