In our work we investigate the development of a novel electrochemical biosensor using graphene as transducer and electroactive membrane proteins as biological recognition elements. Graphene is used as transducer because of its unique properties. namely high surface area, electrical conductivity, ultra-high electron mobility, wide electrochemical potential window, low charge-transfer resistance and reduction of overvoltage. All these properties allow the enhancement of the direct electron transfer between graphene and the membrane proteins. [1,2] Membrane proteins are selected as biosensing element since they are the key factors in cell metabolism, e.g. in cell-cell interactions, signal transduction and transport of ions and nutrients. Thanks to this important function, membrane proteins are a preferred target for pharmaceuticals, with about 60% of consumed drugs addressing them. For applications in electrochemical biosensors, the main problem is related to the denaturation of membrane proteins when they get in contact with electrode surface, so they need to be embedded in a system mimicking their native environment, as the supported lipid bilayers (SLBs). The graphene is synthesized by chemical vapour deposition (CVD) and completely characterized by scanning electron microscopy (SEM) imaging, Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and water contact angles (WCAs) measurements, both before and after peculiar graphene treatments, performed in order to improve its biocompatibility and enhance its interaction with SLBs. The graphene-SLBs interaction is investigated via electrochemical impedance spectroscopy (EIS), using an equivalent circuit for the interpretation of EIS data: its parameters are determined from the best fitting of theoretically calculated impedance plots to experimental ones.

Improvement of CVD-graphene interaction with supported lipid bilayer for the application in novel electrochemical biosensors / Pittori, Martina; Ortolani, Luca; Gentili, Denis; Ruani, P.; Kovtun, Alessandro; Liscio, Andrea; Morandi, Vittorio; Rizzoli, Rita; Santonicola, Mariagabriella. - STAMPA. - (2017), pp. ...-.... (Intervento presentato al convegno Graphene 2017 tenutosi a Barcelona, Spain nel 28-31 Marzo 2017).

Improvement of CVD-graphene interaction with supported lipid bilayer for the application in novel electrochemical biosensors

Martina Pittori;MariaGabriella Santonicola
2017

Abstract

In our work we investigate the development of a novel electrochemical biosensor using graphene as transducer and electroactive membrane proteins as biological recognition elements. Graphene is used as transducer because of its unique properties. namely high surface area, electrical conductivity, ultra-high electron mobility, wide electrochemical potential window, low charge-transfer resistance and reduction of overvoltage. All these properties allow the enhancement of the direct electron transfer between graphene and the membrane proteins. [1,2] Membrane proteins are selected as biosensing element since they are the key factors in cell metabolism, e.g. in cell-cell interactions, signal transduction and transport of ions and nutrients. Thanks to this important function, membrane proteins are a preferred target for pharmaceuticals, with about 60% of consumed drugs addressing them. For applications in electrochemical biosensors, the main problem is related to the denaturation of membrane proteins when they get in contact with electrode surface, so they need to be embedded in a system mimicking their native environment, as the supported lipid bilayers (SLBs). The graphene is synthesized by chemical vapour deposition (CVD) and completely characterized by scanning electron microscopy (SEM) imaging, Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and water contact angles (WCAs) measurements, both before and after peculiar graphene treatments, performed in order to improve its biocompatibility and enhance its interaction with SLBs. The graphene-SLBs interaction is investigated via electrochemical impedance spectroscopy (EIS), using an equivalent circuit for the interpretation of EIS data: its parameters are determined from the best fitting of theoretically calculated impedance plots to experimental ones.
2017
Graphene 2017
04 Pubblicazione in atti di convegno::04d Abstract in atti di convegno
Improvement of CVD-graphene interaction with supported lipid bilayer for the application in novel electrochemical biosensors / Pittori, Martina; Ortolani, Luca; Gentili, Denis; Ruani, P.; Kovtun, Alessandro; Liscio, Andrea; Morandi, Vittorio; Rizzoli, Rita; Santonicola, Mariagabriella. - STAMPA. - (2017), pp. ...-.... (Intervento presentato al convegno Graphene 2017 tenutosi a Barcelona, Spain nel 28-31 Marzo 2017).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1016877
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact