In the last decades the definition of a suitable monitoring system for identifying the dynamic behavior of structures has had a central position in the civil engineering research area. The vibration analysis leads to the recognition of the reference state of structures which is essential to determine the integrity level when extreme events occur, such as earthquakes. The latest seismic events occurred in the world have shown the essential role of the new passive seismic techniques which aim to protect structures and the importance of supervising the building construction operations and the adopted improvement measures. In this work the structural monitoring of the civic tower located in Rieti is presented. In the tower a non-conventional TMD has been installed via an inter-story isolation system at the top floor by means of High Damping Rubber Bearings (HDRB). The general goal is to define a monitoring system suitable with this experimental case through the vibration analysis. Several aspects will be taken into account: the choice of sensors setup, the measured quantities and the extraction of structural information. Firstly this will allow to define the structure’s reference state featured by frequencies, damping ratios and mode shapes. Moreover the effective design of the monitoring system would lead to the characterization of the dynamic behavior of the structure equipped with a passive vibration control system. Different tests have been carried forward: ambient vibration test (AVT), forced vibration test (FVT) with vibrodyne and seismic test (ST). The AVT and the FVT enable to define the monitoring system and check the reliability of the adopted identification tools, among which an Output Only algorithm stands out: the Observer Kalman Filter System Id. On the other hand the ST will point out some preliminary information about the dynamic behaviour of the structure equipped with a non conventional Tuned Mass Damper referring it to higher levels of vibrations.

Vibration analysis of the civic tower in Rieti / Tronci E., M; Pietrosanti, D.; Cordisco, Giuseppe; De Angelis, M.. - In: PROCEDIA ENGINEERING. - ISSN 1877-7058. - ELETTRONICO. - 199:(2017), pp. 2268-2273. (Intervento presentato al convegno EURODYN 2017 tenutosi a Sapienza Università di Roma nel Settembre 2017) [10.1016/j.proeng.2017.09.254].

Vibration analysis of the civic tower in Rieti

Pietrosanti D.;De Angelis M.
2017

Abstract

In the last decades the definition of a suitable monitoring system for identifying the dynamic behavior of structures has had a central position in the civil engineering research area. The vibration analysis leads to the recognition of the reference state of structures which is essential to determine the integrity level when extreme events occur, such as earthquakes. The latest seismic events occurred in the world have shown the essential role of the new passive seismic techniques which aim to protect structures and the importance of supervising the building construction operations and the adopted improvement measures. In this work the structural monitoring of the civic tower located in Rieti is presented. In the tower a non-conventional TMD has been installed via an inter-story isolation system at the top floor by means of High Damping Rubber Bearings (HDRB). The general goal is to define a monitoring system suitable with this experimental case through the vibration analysis. Several aspects will be taken into account: the choice of sensors setup, the measured quantities and the extraction of structural information. Firstly this will allow to define the structure’s reference state featured by frequencies, damping ratios and mode shapes. Moreover the effective design of the monitoring system would lead to the characterization of the dynamic behavior of the structure equipped with a passive vibration control system. Different tests have been carried forward: ambient vibration test (AVT), forced vibration test (FVT) with vibrodyne and seismic test (ST). The AVT and the FVT enable to define the monitoring system and check the reliability of the adopted identification tools, among which an Output Only algorithm stands out: the Observer Kalman Filter System Id. On the other hand the ST will point out some preliminary information about the dynamic behaviour of the structure equipped with a non conventional Tuned Mass Damper referring it to higher levels of vibrations.
2017
EURODYN 2017
vibration analysis; structural health monitoring; observer Kalman filter identification algorithm
04 Pubblicazione in atti di convegno::04c Atto di convegno in rivista
Vibration analysis of the civic tower in Rieti / Tronci E., M; Pietrosanti, D.; Cordisco, Giuseppe; De Angelis, M.. - In: PROCEDIA ENGINEERING. - ISSN 1877-7058. - ELETTRONICO. - 199:(2017), pp. 2268-2273. (Intervento presentato al convegno EURODYN 2017 tenutosi a Sapienza Università di Roma nel Settembre 2017) [10.1016/j.proeng.2017.09.254].
File allegati a questo prodotto
File Dimensione Formato  
Tronci_Vibration_2017.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1015151
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact