The proximity between two different railway supply systems, ac and dc power systems, could bring about to the propagation of interferences from one system to the other. Furthermore, unexpected overvoltages and overcurrents could appear due to the breakdown of equipments installed in the interconnection point. The protection system considered is placed in the Chiasso station, where there are several constraints, among which a limited space available to realize a traditional separation section. The present paper proposes a new protection system from faults between the Italian d.c. railway line and the Switzerland a.c. one. The innovative system will be in operation in a short time. In order to simulate several phenomena, a specific Matlab-Simulink model has been implemented and used to simulate the system proposed.

Innovative protection system for separation section between 15 kV a.c. And 3 kV d.c. Railway networks / Buffarini, G. G.; Trezza, G.; Consalvi, R.; Lamedica, R.; Ruvio, A.; Muzi, S.. - ELETTRONICO. - (2016), pp. 1-5. (Intervento presentato al convegno 2016 AEIT International Annual Conference, AEIT 2016 tenutosi a ita nel 2016) [10.23919/AEIT.2016.7892778].

Innovative protection system for separation section between 15 kV a.c. And 3 kV d.c. Railway networks

Lamedica, R.;Ruvio, A.;
2016

Abstract

The proximity between two different railway supply systems, ac and dc power systems, could bring about to the propagation of interferences from one system to the other. Furthermore, unexpected overvoltages and overcurrents could appear due to the breakdown of equipments installed in the interconnection point. The protection system considered is placed in the Chiasso station, where there are several constraints, among which a limited space available to realize a traditional separation section. The present paper proposes a new protection system from faults between the Italian d.c. railway line and the Switzerland a.c. one. The innovative system will be in operation in a short time. In order to simulate several phenomena, a specific Matlab-Simulink model has been implemented and used to simulate the system proposed.
2016
2016 AEIT International Annual Conference, AEIT 2016
ac railway; dc railway; isolator; modelling; poc architecture; protection system; computer networks and communications; hardware and architecture; energy engineering and power technology; renewable energy; sustainability and the environment
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Innovative protection system for separation section between 15 kV a.c. And 3 kV d.c. Railway networks / Buffarini, G. G.; Trezza, G.; Consalvi, R.; Lamedica, R.; Ruvio, A.; Muzi, S.. - ELETTRONICO. - (2016), pp. 1-5. (Intervento presentato al convegno 2016 AEIT International Annual Conference, AEIT 2016 tenutosi a ita nel 2016) [10.23919/AEIT.2016.7892778].
File allegati a questo prodotto
File Dimensione Formato  
Buffarini_Innovative-protection_2016.pdf

solo gestori archivio

Note: https://ieeexplore.ieee.org/document/7892778/
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1015142
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact