Intravenous (IV) infusion of adenosine represents the gold standard for measuring fractional flow reserve (FFR). However, IV adenosine is more expensive and time-consuming compared with intracoronary (IC) boluses of adenosine. We conducted a meta-analysis of studies comparing IC with IV adenosine for FFR assessment in the same coronary lesions. We searched for studies comparing IC with IV adenosine and reporting absolute FFR values or rate of abnormal FFR for both routes. Prespecified subgroup analysis was performed to appraise studies using low-dose (<100 μg) or high-dose IC adenosine (≥100 μg). We retrieved 11 studies amounting to 587 patients and 621 lesions. Six studies evaluated low-dose IC boluses (15 to 80 μg) and 5 studies high-dose boluses (120 to 600 μg). Absolute FFR values were slightly, yet significantly lower with IV adenosine compared with IC adenosine (mean difference 0.02, 95% confidence interval [CI] 0.00 to 0.03, p = 0.02). This difference, however, did not translate into a significant difference in the rate of abnormal FFR between IC and IV adenosine (hazard ratio 0.93, 95% CI 0.76 to 1.13, p = 0.57); moreover, no statistically significant difference was observed between low-dose and high-dose IC adenosine subgroups. Adverse events were less frequent with IC adenosine compared with IV adenosine (risk ratio 0.17, 95% CI 0.07 to 0.43, p <0.001). In conclusion, IC administration of adenosine, although inducing a slightly lower amount of hyperemia compared with IV infusion of adenosine, yields a similar diagnostic accuracy in identifying hemodynamically significant coronary stenosis and is better tolerated by the patients.

Meta-Analysis of Head-to-Head Comparison of Intracoronary Versus Intravenous Adenosine for the Assessment of Fractional Flow Reserve / Rigattieri, Stefano; BIONDI ZOCCAI, Giuseppe; Sciahbasi, Alessandro; Di Russo, Cristian; Cera, Maria; Patrizi, Roberto; Fedele, Silvio; Berni, Andrea; Pugliese, FRANCESCO ROCCO. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - STAMPA. - 120:4(2017), pp. 563-568. [10.1016/j.amjcard.2017.05.024]

Meta-Analysis of Head-to-Head Comparison of Intracoronary Versus Intravenous Adenosine for the Assessment of Fractional Flow Reserve

BIONDI ZOCCAI, GIUSEPPE;BERNI, Andrea;PUGLIESE, FRANCESCO ROCCO
2017

Abstract

Intravenous (IV) infusion of adenosine represents the gold standard for measuring fractional flow reserve (FFR). However, IV adenosine is more expensive and time-consuming compared with intracoronary (IC) boluses of adenosine. We conducted a meta-analysis of studies comparing IC with IV adenosine for FFR assessment in the same coronary lesions. We searched for studies comparing IC with IV adenosine and reporting absolute FFR values or rate of abnormal FFR for both routes. Prespecified subgroup analysis was performed to appraise studies using low-dose (<100 μg) or high-dose IC adenosine (≥100 μg). We retrieved 11 studies amounting to 587 patients and 621 lesions. Six studies evaluated low-dose IC boluses (15 to 80 μg) and 5 studies high-dose boluses (120 to 600 μg). Absolute FFR values were slightly, yet significantly lower with IV adenosine compared with IC adenosine (mean difference 0.02, 95% confidence interval [CI] 0.00 to 0.03, p = 0.02). This difference, however, did not translate into a significant difference in the rate of abnormal FFR between IC and IV adenosine (hazard ratio 0.93, 95% CI 0.76 to 1.13, p = 0.57); moreover, no statistically significant difference was observed between low-dose and high-dose IC adenosine subgroups. Adverse events were less frequent with IC adenosine compared with IV adenosine (risk ratio 0.17, 95% CI 0.07 to 0.43, p <0.001). In conclusion, IC administration of adenosine, although inducing a slightly lower amount of hyperemia compared with IV infusion of adenosine, yields a similar diagnostic accuracy in identifying hemodynamically significant coronary stenosis and is better tolerated by the patients.
2017
adenosine; coronary angiography; coronary artery disease; coronary circulation; coronary vessels; dose-response relationship, drug; fractional flow reserve, myocardial; infusions, intra-arterial; infusions, intravenous; severity of illness index; vasodilation; vasodilator agents; cardiology and cardiovascular medicine
01 Pubblicazione su rivista::01a Articolo in rivista
Meta-Analysis of Head-to-Head Comparison of Intracoronary Versus Intravenous Adenosine for the Assessment of Fractional Flow Reserve / Rigattieri, Stefano; BIONDI ZOCCAI, Giuseppe; Sciahbasi, Alessandro; Di Russo, Cristian; Cera, Maria; Patrizi, Roberto; Fedele, Silvio; Berni, Andrea; Pugliese, FRANCESCO ROCCO. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - STAMPA. - 120:4(2017), pp. 563-568. [10.1016/j.amjcard.2017.05.024]
File allegati a questo prodotto
File Dimensione Formato  
Rigattieri_Meta-Analusis_2017.pdf

solo gestori archivio

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 925.22 kB
Formato Adobe PDF
925.22 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1012274
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 11
social impact