The paper discusses the potential and reliability of identified parametric non-physical linear systems with increasing model order in closely reproducing the experimental seismic response of a complex monumental structure. The measured vibration data have been extracted from a multi-sensor system, installed for the long-term structural monitoring of an historical monumental church, the Basilica S. Maria di Collemaggio, which was heavily damaged in the 2009 L'Aquila earthquake. The monitoring system has been used as test bed due to the specific features of the wireless sensor networks, purposely designed to detect earthquake-induced vibrations. Both frequency and time domain methods have been employed for the data processing and interpretation. The subspace state-space system identification (4SID) has been used to identify a class of parametric non-physical linear systems, which are able to reproduce the measured seismic response and are successively discussed for their effectiveness in the mechanical interpretation of the structural behavior.

Identification of parametric non-physical linear systems to reproduce seismic induced response / Gattulli, Vincenzo; Potenza, F.; Lepidi, M.; Di Sabatino, U.. - (2015).

Identification of parametric non-physical linear systems to reproduce seismic induced response

GATTULLI, VINCENZO;
2015

Abstract

The paper discusses the potential and reliability of identified parametric non-physical linear systems with increasing model order in closely reproducing the experimental seismic response of a complex monumental structure. The measured vibration data have been extracted from a multi-sensor system, installed for the long-term structural monitoring of an historical monumental church, the Basilica S. Maria di Collemaggio, which was heavily damaged in the 2009 L'Aquila earthquake. The monitoring system has been used as test bed due to the specific features of the wireless sensor networks, purposely designed to detect earthquake-induced vibrations. Both frequency and time domain methods have been employed for the data processing and interpretation. The subspace state-space system identification (4SID) has been used to identify a class of parametric non-physical linear systems, which are able to reproduce the measured seismic response and are successively discussed for their effectiveness in the mechanical interpretation of the structural behavior.
2015
SHMII 2015 - 7th International Conference on Structural Health Monitoring of Intelligent Infrastructure
9781510821071
Building and Construction; Civil and Structural Engineering; Artificial Intelligence
02 Pubblicazione su volume::02b Commentario
Identification of parametric non-physical linear systems to reproduce seismic induced response / Gattulli, Vincenzo; Potenza, F.; Lepidi, M.; Di Sabatino, U.. - (2015).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/975034
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact