The Lunar Electromagnetic Monitor in X-rays (LEM-X) is a proposed all-sky X-ray observatory for the lunar surface, designed to detect and localize high-energy transients and monitor variable X-ray sources over the 2–50 keV energy range. LEM-X is based on modular coded-aperture cameras, each combining a coded mask with a focal plane of four large-area Silicon Drift Detectors, and providing a ∼ 1 steradian Field of View at 25% effective area and ∼ 1 arcmin Point-Source Location Accuracy. The imaging performance of the camera depends critically on the relative alignment of mask and detectors, which must be assembled within strict tolerances and remain stable under the expected operating environmental conditions. In this contribution we present a comprehensive analysis of the camera internal alignment budget. We classify the error contributions, assess the possibility of their correction both on ground and in flight, and estimate the expected magnitude for each degree of freedom. Using an end-to-end simulation and reconstruction chain, we quantify the impact of each contribution on sensitivity, flux estimation, and reconstructed source position, identifying the deformation components most critical to imaging quality. Comparison with the expected values shows the robustness of the design against the foreseen misalignments, and provides quantitative guidance for the camera mechanical and thermal design.
Internal alignment of the LEM-X coded-mask camera: classification of error contributions and impact on imaging performance / Nuti, Alessio; Giancarli, Edoardo; Evangelista, Yuri; Ceraudo, Francesco; Dilillo, Giuseppe; Campana, Riccardo; Della Casa, Giovanni; Del Monte, Ettore; Feroci, Marco; Fiorini, Mauro; Lombardi, Giovanni; Rapisarda, Massimo; Esposito, Francesca; Donnarumma, Immacolata; Cortesi, Ugo; Pisanu, Tonino; Turchi, Alessandro; Gai, Marco; Argan, Andrea. - (2026). [10.1117/12.3104507].
Internal alignment of the LEM-X coded-mask camera: classification of error contributions and impact on imaging performance
Giancarli, Edoardo;
2026
Abstract
The Lunar Electromagnetic Monitor in X-rays (LEM-X) is a proposed all-sky X-ray observatory for the lunar surface, designed to detect and localize high-energy transients and monitor variable X-ray sources over the 2–50 keV energy range. LEM-X is based on modular coded-aperture cameras, each combining a coded mask with a focal plane of four large-area Silicon Drift Detectors, and providing a ∼ 1 steradian Field of View at 25% effective area and ∼ 1 arcmin Point-Source Location Accuracy. The imaging performance of the camera depends critically on the relative alignment of mask and detectors, which must be assembled within strict tolerances and remain stable under the expected operating environmental conditions. In this contribution we present a comprehensive analysis of the camera internal alignment budget. We classify the error contributions, assess the possibility of their correction both on ground and in flight, and estimate the expected magnitude for each degree of freedom. Using an end-to-end simulation and reconstruction chain, we quantify the impact of each contribution on sensitivity, flux estimation, and reconstructed source position, identifying the deformation components most critical to imaging quality. Comparison with the expected values shows the robustness of the design against the foreseen misalignments, and provides quantitative guidance for the camera mechanical and thermal design.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


