Hypogea are characterized by stable temperature (T) and high levels of relative humidity (RH). If measuring T is not complex through platinum resistance sensor (Pt 100 sensor), most thin film capacitive sensors for measuring RH can experience issues in damp environments. Indeed, in such conditions, water vapour can condense on the dielectric material, implying a significant error in the RH measurement. In this research, we study the performance of different kind of thermo-hygrometers within the hypogeum of Tomba della Scimmia (Chiusi, Italy). In this site, indoor climate monitoring has started in 2011 representing a unicum for the length of T and RH data series. It was found that the hygrometer commonly used for indoor monitoring is unable to detect any fasten RH drop if exposed to very damp environments. Even if hygrometers specifically developed to avoid condensation were used, they might provide the same erroneous RH values anyway.

Monitoring of relative humidity in extreme environments: the hypogeum of “Tomba della Scimmia” / Frasca, Francesca; Caratelli, Alessia; Siani, Anna Maria. - (2023). (Intervento presentato al convegno MetroArcheo 2023 IMEKO international conference on Metrology for Archaeology and Cultural Heritage tenutosi a Roma: Italia).

Monitoring of relative humidity in extreme environments: the hypogeum of “Tomba della Scimmia”

Francesca Frasca
;
Anna Maria Siani
2023

Abstract

Hypogea are characterized by stable temperature (T) and high levels of relative humidity (RH). If measuring T is not complex through platinum resistance sensor (Pt 100 sensor), most thin film capacitive sensors for measuring RH can experience issues in damp environments. Indeed, in such conditions, water vapour can condense on the dielectric material, implying a significant error in the RH measurement. In this research, we study the performance of different kind of thermo-hygrometers within the hypogeum of Tomba della Scimmia (Chiusi, Italy). In this site, indoor climate monitoring has started in 2011 representing a unicum for the length of T and RH data series. It was found that the hygrometer commonly used for indoor monitoring is unable to detect any fasten RH drop if exposed to very damp environments. Even if hygrometers specifically developed to avoid condensation were used, they might provide the same erroneous RH values anyway.
2023
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1738494
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact