: The lateral transpsoas approach (extreme lateral interbody fusion, or XLIF) allows surgeons to use various lordotic cage sizes to help restore intervertebral disk height, correct sagittal alignment, and improve fusion rates. The use of standalone devices has consistently raised doubts due to the high risk of complications and inadequate functional recovery that a circumferential arthrodesis can support. The recent introduction of a novel XLIF cage with adapted lateral plate fixation (XLPF) may further enhance the structural rigidity, consolidating the cage and plate into a singular modular entity. Nine patients from our surgical centers underwent a procedure of 1-level XLIF with XLPF in selected cases. We observed that XLPF does not extend the intraoperative footprint and provides immediate rigidity to the anterior column without any additional risk of complications and with minimal increased time compared to the traditional cage implant procedure. Although it has been shown that the use of interbody fusion cages with supplemental posterior fixation improves stabilization in all directions, the technique of standalone lateral cages may also have a place in spine surgery in that the stability may be sufficient in selected cases, such as junctional syndrome and in some forms of degenerative scoliosis.

Extreme Lateral Interbody Fusion (XLIF) with Lateral Modular Plate Fixation: Preliminary Report on Clinical and Radiological Outcomes / Armocida, Daniele; Perna, Andrea; Cofano, Fabio; Cimatti, Marco; Arcidiacono, Umberto Aldo; Marengo, Nicola; Ajello, Marco; Garbossa, Diego; Proietti, Luca; Tamburrelli, Francesco Ciro; Maiotti, Marco; Santoro, Antonio; Frati, Alessandro. - (2023), pp. 431-437. - ACTA NEUROCHIRURGICA. SUPPLEMENTUM. [10.1007/978-3-031-36084-8_66].

Extreme Lateral Interbody Fusion (XLIF) with Lateral Modular Plate Fixation: Preliminary Report on Clinical and Radiological Outcomes

Armocida, Daniele;Cimatti, Marco;Arcidiacono, Umberto Aldo;Proietti, Luca;Santoro, Antonio;Frati, Alessandro
2023

Abstract

: The lateral transpsoas approach (extreme lateral interbody fusion, or XLIF) allows surgeons to use various lordotic cage sizes to help restore intervertebral disk height, correct sagittal alignment, and improve fusion rates. The use of standalone devices has consistently raised doubts due to the high risk of complications and inadequate functional recovery that a circumferential arthrodesis can support. The recent introduction of a novel XLIF cage with adapted lateral plate fixation (XLPF) may further enhance the structural rigidity, consolidating the cage and plate into a singular modular entity. Nine patients from our surgical centers underwent a procedure of 1-level XLIF with XLPF in selected cases. We observed that XLPF does not extend the intraoperative footprint and provides immediate rigidity to the anterior column without any additional risk of complications and with minimal increased time compared to the traditional cage implant procedure. Although it has been shown that the use of interbody fusion cages with supplemental posterior fixation improves stabilization in all directions, the technique of standalone lateral cages may also have a place in spine surgery in that the stability may be sufficient in selected cases, such as junctional syndrome and in some forms of degenerative scoliosis.
2023
The Funnel: From the Skull Base to the Sacrum
9783031360831
9783031360848
Minimally invasive spine surgery; Modular plate fixation; Spine; XLIF
02 Pubblicazione su volume::02a Capitolo o Articolo
Extreme Lateral Interbody Fusion (XLIF) with Lateral Modular Plate Fixation: Preliminary Report on Clinical and Radiological Outcomes / Armocida, Daniele; Perna, Andrea; Cofano, Fabio; Cimatti, Marco; Arcidiacono, Umberto Aldo; Marengo, Nicola; Ajello, Marco; Garbossa, Diego; Proietti, Luca; Tamburrelli, Francesco Ciro; Maiotti, Marco; Santoro, Antonio; Frati, Alessandro. - (2023), pp. 431-437. - ACTA NEUROCHIRURGICA. SUPPLEMENTUM. [10.1007/978-3-031-36084-8_66].
File allegati a questo prodotto
File Dimensione Formato  
Armocida2024.pdf

solo gestori archivio

Note: Armocida_Extreme Lateral Interbody Fusion (XLIF)_2023
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 720.39 kB
Formato Adobe PDF
720.39 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1712221
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact