The importance of tourism in Italy is widely known, being the second country in Europe in terms of hotels facilities supply. Due to the high energy demand of hotels, several researchers investigated solutions to transform them into sustainable and energy efficiencies buildings. Artificial lighting plays a key role in the energy consumption of a building, as highlighted in the literature. To quantify its impact, European standards defined the LENI (Lighting Energy Numerical Indicator), able to evaluate the lighting consumption of a building, taking into account the daylight availability. Currently, the re-lamping strategies is a common practice to obtain high energy savings. However, few works investigate the possibility of applying lighting control strategies of an Italian hotel equipped with LEDs lamps. This study covers this gap, proposing a typical Italian hotel and evaluating the impact of those lighting control systems on electricity consumption. LENICALC software is chosen for carrying out the simulations. Results underlined the benefits of the application of those lighting control techniques, in terms of energy and economic savings for this building typology.

The influence of lighting control techniques on the energy consumption of an Italian hotel / Pompei, L.; Bisegna, F.; Grignaffini, S.; Blaso, L.; Fumagalli, S.. - (2022), pp. 1-5. [10.1109/EEEIC/ICPSEurope54979.2022.9854669].

The influence of lighting control techniques on the energy consumption of an Italian hotel

Pompei L.
;
Bisegna F.;Grignaffini S.;
2022

Abstract

The importance of tourism in Italy is widely known, being the second country in Europe in terms of hotels facilities supply. Due to the high energy demand of hotels, several researchers investigated solutions to transform them into sustainable and energy efficiencies buildings. Artificial lighting plays a key role in the energy consumption of a building, as highlighted in the literature. To quantify its impact, European standards defined the LENI (Lighting Energy Numerical Indicator), able to evaluate the lighting consumption of a building, taking into account the daylight availability. Currently, the re-lamping strategies is a common practice to obtain high energy savings. However, few works investigate the possibility of applying lighting control strategies of an Italian hotel equipped with LEDs lamps. This study covers this gap, proposing a typical Italian hotel and evaluating the impact of those lighting control systems on electricity consumption. LENICALC software is chosen for carrying out the simulations. Results underlined the benefits of the application of those lighting control techniques, in terms of energy and economic savings for this building typology.
2022
2022 IEEE International Conference on Environment and Electrical Engineering and 2022 IEEE Industrial and Commercial Power Systems Europe, EEEIC / I and CPS Europe 2022
978-1-6654-8537-1
hotel; LENI; LENICALC software; lighting consumptions; lighting control systems
02 Pubblicazione su volume::02a Capitolo o Articolo
The influence of lighting control techniques on the energy consumption of an Italian hotel / Pompei, L.; Bisegna, F.; Grignaffini, S.; Blaso, L.; Fumagalli, S.. - (2022), pp. 1-5. [10.1109/EEEIC/ICPSEurope54979.2022.9854669].
File allegati a questo prodotto
File Dimensione Formato  
Pompei_The influence_2022.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 234.31 kB
Formato Adobe PDF
234.31 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1655375
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact