Gait Trainer (GT) and the Lokomat (Loko) are two commercial robotic devices developed for assist task-oriented, intensive practice of walking in neurological patients. Despite the many studies involving these devices, there are not specific studies comparing electromyography (EMG) activity during sessions of walking training performed using these devices. This study aimed to explore the differences in the EMG patterns between these two devices and in respect overground walking. EMG of eight lower limb muscles were bilaterally recorded and analyzed in one healthy subject. Thigh muscles were more active during GTsession, whereas shank muscles during Loko-session. Furthermore, decreasing the guidance assistance of Loko (i.e. the percentage of force applied by the robot in respect to that needed for following the predetermined trajectory, training), all the muscles showed an increment of the EMG signal. These results showed clear differences in muscle activation patterns between the two systems and, as expected, quite different from the pattern observed in over-ground locomotion. These results are of importance for the correct use of robotic devices in gait rehabilitation and would represent the preliminary step to address their correct use in neurologically impaired subjects.

An EMG pattern comparison of exoskeleton vs. end-effector robotic device for assisted walking training / Morone, Giovanni; Iosa, Marco; Tamburella, Federica; Muzzioli, Luca; Pisotta, Iolanda; Moreno, Juan C.; Pons, José L.; Paolucci, Stefano; Cincotti, Febo; Molinari, Marco. - (2014), pp. 563-567. - BIOSYSTEMS & BIOROBOTICS. [10.1007/978-3-319-08072-7_82].

An EMG pattern comparison of exoskeleton vs. end-effector robotic device for assisted walking training

Iosa, Marco;Muzzioli, Luca;Pisotta, Iolanda;Cincotti, Febo;
2014

Abstract

Gait Trainer (GT) and the Lokomat (Loko) are two commercial robotic devices developed for assist task-oriented, intensive practice of walking in neurological patients. Despite the many studies involving these devices, there are not specific studies comparing electromyography (EMG) activity during sessions of walking training performed using these devices. This study aimed to explore the differences in the EMG patterns between these two devices and in respect overground walking. EMG of eight lower limb muscles were bilaterally recorded and analyzed in one healthy subject. Thigh muscles were more active during GTsession, whereas shank muscles during Loko-session. Furthermore, decreasing the guidance assistance of Loko (i.e. the percentage of force applied by the robot in respect to that needed for following the predetermined trajectory, training), all the muscles showed an increment of the EMG signal. These results showed clear differences in muscle activation patterns between the two systems and, as expected, quite different from the pattern observed in over-ground locomotion. These results are of importance for the correct use of robotic devices in gait rehabilitation and would represent the preliminary step to address their correct use in neurologically impaired subjects.
2014
Replace, Repair, Restore, Relieve – Bridging Clinical and Engineering Solutions in Neurorehabilitation. Proceedings of the 2nd International Conference on NeuroRehabilitation (ICNR2014), Aalborg, 24–26 June, 2014 ABC
978-3-319-08071-0
978-3-319-08072-7
Biomedical Engineering; Mechanical Engineering; Artificial Intelligence
02 Pubblicazione su volume::02a Capitolo, Articolo o Contributo
An EMG pattern comparison of exoskeleton vs. end-effector robotic device for assisted walking training / Morone, Giovanni; Iosa, Marco; Tamburella, Federica; Muzzioli, Luca; Pisotta, Iolanda; Moreno, Juan C.; Pons, José L.; Paolucci, Stefano; Cincotti, Febo; Molinari, Marco. - (2014), pp. 563-567. - BIOSYSTEMS & BIOROBOTICS. [10.1007/978-3-319-08072-7_82].
File allegati a questo prodotto
File Dimensione Formato  
Morone_An-EMG-pattern_2014.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 365.25 kB
Formato Adobe PDF
365.25 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1196380
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 4
social impact