The High Luminosity Large Hadron Collider (HL-LHC) Project at CERN calls for increasing beam brightness and intensity. In this scenario, most equipment has to be redesigned and rebuilt. In particular, beam intercepting devices (such as dumps, collimators, absorbers and scrapers) have to withstand impact or scraping of the new intense HL-LHC beams without failure. Furthermore, minimizing the electromagnetic beam-device interactions is also a key design driver since they can lead to beam instabilities and excessive thermo-mechanical loading of devices. In this context, the present study assesses the conceptual design quality of the new LHC injection protection absorber, the Target Dump Injection Segmented (TDIS), from an electromagnetic and thermo-mechanical perspective. This contribution analyzes the thermo-mechanical response of the device considering two cases: an accidental beam impact scenario and another accidental scenario with complete failure of the RFcontacts. In addition, this paper presents the preliminary results from the simulation of the energy deposited by the two counter-rotating beams circulating in the device.

Design of the Target Dump Injection Segmented (TDIS) in the framework of the High Luminosity Large Hadron Collider (HL-LHC) project / Teofili, L.; Migliorati, M.; Carbajo, D.; Lamas, I.; Perillo, A.. - (2018), pp. 122-126. [10.18429/JACoW-HB2018-TUP2WE04].

Design of the Target Dump Injection Segmented (TDIS) in the framework of the High Luminosity Large Hadron Collider (HL-LHC) project

L. Teofili;M. Migliorati;
2018

Abstract

The High Luminosity Large Hadron Collider (HL-LHC) Project at CERN calls for increasing beam brightness and intensity. In this scenario, most equipment has to be redesigned and rebuilt. In particular, beam intercepting devices (such as dumps, collimators, absorbers and scrapers) have to withstand impact or scraping of the new intense HL-LHC beams without failure. Furthermore, minimizing the electromagnetic beam-device interactions is also a key design driver since they can lead to beam instabilities and excessive thermo-mechanical loading of devices. In this context, the present study assesses the conceptual design quality of the new LHC injection protection absorber, the Target Dump Injection Segmented (TDIS), from an electromagnetic and thermo-mechanical perspective. This contribution analyzes the thermo-mechanical response of the device considering two cases: an accidental beam impact scenario and another accidental scenario with complete failure of the RFcontacts. In addition, this paper presents the preliminary results from the simulation of the energy deposited by the two counter-rotating beams circulating in the device.
2018
Proceedings of HB2018
978-3-95450-202-8
particle accelerator, Synchrotron, instability, coupling impedance
02 Pubblicazione su volume::02a Capitolo o Articolo
Design of the Target Dump Injection Segmented (TDIS) in the framework of the High Luminosity Large Hadron Collider (HL-LHC) project / Teofili, L.; Migliorati, M.; Carbajo, D.; Lamas, I.; Perillo, A.. - (2018), pp. 122-126. [10.18429/JACoW-HB2018-TUP2WE04].
File allegati a questo prodotto
File Dimensione Formato  
tup2we04.pdf

accesso aperto

Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.94 MB
Formato Adobe PDF
2.94 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1156618
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact