The 6th of April 2009, a quite strong earthquake of magnitude ML =5.8 (Mw=6.3), struck in the city of L'Aquila. The seismic event caused serious injure to several masonry buildings, compromising a large part of the valuable historical and architectural heritage. The present work deals with seismic performance evaluation of an existing mixed masonry-reinforced concrete building in downtown L'Aquila city. A comprehensive discussion on the current limit capacity of the building based on the visual inspections of the occurred seismic damage, the experimental data from a wide campaign of on-site tests on the material properties, the results of numerical simulations from different naturally discrete models of the mixed masonry-reinforced concrete structure are presented. The seismic performance is evaluated through well-recognized N2 nonlinear static procedure. The Frame by Macro-Elements method is used to define an equivalent 3D frame representation of the structure. The obtained numerical results are directly compared with the surveyed damages.

Seismic performance of a mixed masonry-reinforced concrete building / Gattulli, Vincenzo; Potenza, Francesco; Valvona, Filippo. - (2015), pp. 293-312. [10.4018/978-1-4666-8286-3.ch009].

Seismic performance of a mixed masonry-reinforced concrete building

GATTULLI, VINCENZO;
2015

Abstract

The 6th of April 2009, a quite strong earthquake of magnitude ML =5.8 (Mw=6.3), struck in the city of L'Aquila. The seismic event caused serious injure to several masonry buildings, compromising a large part of the valuable historical and architectural heritage. The present work deals with seismic performance evaluation of an existing mixed masonry-reinforced concrete building in downtown L'Aquila city. A comprehensive discussion on the current limit capacity of the building based on the visual inspections of the occurred seismic damage, the experimental data from a wide campaign of on-site tests on the material properties, the results of numerical simulations from different naturally discrete models of the mixed masonry-reinforced concrete structure are presented. The seismic performance is evaluated through well-recognized N2 nonlinear static procedure. The Frame by Macro-Elements method is used to define an equivalent 3D frame representation of the structure. The obtained numerical results are directly compared with the surveyed damages.
2015
Handbook of Research on Seismic Assessment and Rehabilitation of Historic Structures
9781466682870
Engineering (all); Arts and Humanities (all)
02 Pubblicazione su volume::02b Commentario
Seismic performance of a mixed masonry-reinforced concrete building / Gattulli, Vincenzo; Potenza, Francesco; Valvona, Filippo. - (2015), pp. 293-312. [10.4018/978-1-4666-8286-3.ch009].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/974980
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact