Conclusion. According to the first series of implanted patients, Esteem 2† technology can be regarded as a safe and reliable system for hearing restoration in case of moderate to severe sensorineural hearing loss. Objectives. To assess the benefit deriving from implantation of a totally implantable middle ear device in subjects affected by moderate to severe sensorineural hearing loss, the Esteem 2† (Envoy Medical), as measured through pure tone audiometry testing carried out during the different postoperative fitting sessions. Patients and methods. Six patients have been operated on since July 2007. Selection was carried out via preoperative audiometric tests and thorough counseling, which considered information on previous experience with conventional hearing aids as well as each patient’s motivation to undergo a surgical application. Specific surgical training is needed to accommodate routine surgical steps along with less familiar steps, such as placement of cement material and overall fixation of the system. Results. The surgical procedure took a long time, but a reduced duration was recorded in the last procedure compared with the first one. The implantation process induced a deterioration in hearing thresholds, which fully recovered after activation of the device. A postoperative hearing gain could be measured in all three patients: in this regard, the perceived quality of sound was shown to be better than could be expected by the measurable hearing gain.

Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem†, Envoy / Barbara, Maurizio; Manni, V; Monini, Simonetta. - In: ACTA OTO-LARYNGOLOGICA. - ISSN 0001-6489. - STAMPA. - 129:(2009), pp. 429-432. [10.1080/00016480802593505]

Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem†, Envoy

BARBARA, Maurizio;MONINI, Simonetta
2009

Abstract

Conclusion. According to the first series of implanted patients, Esteem 2† technology can be regarded as a safe and reliable system for hearing restoration in case of moderate to severe sensorineural hearing loss. Objectives. To assess the benefit deriving from implantation of a totally implantable middle ear device in subjects affected by moderate to severe sensorineural hearing loss, the Esteem 2† (Envoy Medical), as measured through pure tone audiometry testing carried out during the different postoperative fitting sessions. Patients and methods. Six patients have been operated on since July 2007. Selection was carried out via preoperative audiometric tests and thorough counseling, which considered information on previous experience with conventional hearing aids as well as each patient’s motivation to undergo a surgical application. Specific surgical training is needed to accommodate routine surgical steps along with less familiar steps, such as placement of cement material and overall fixation of the system. Results. The surgical procedure took a long time, but a reduced duration was recorded in the last procedure compared with the first one. The implantation process induced a deterioration in hearing thresholds, which fully recovered after activation of the device. A postoperative hearing gain could be measured in all three patients: in this regard, the perceived quality of sound was shown to be better than could be expected by the measurable hearing gain.
2009
01 Pubblicazione su rivista::01a Articolo in rivista
Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem†, Envoy / Barbara, Maurizio; Manni, V; Monini, Simonetta. - In: ACTA OTO-LARYNGOLOGICA. - ISSN 0001-6489. - STAMPA. - 129:(2009), pp. 429-432. [10.1080/00016480802593505]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/89133
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 24
social impact