This study evaluates X-ray exposure in patient undergoing abdominal extra-vascular interventional procedures by means of Digital Imaging and COmmunications in Medicine (DICOM) image headers and Monte Carlo simulation. The main aim was to assess the effective and equivalent doses, under the hypothesis of their correlation with the dose area product (DAP) measured during each examination. This allows to collect dosimetric information about each patient and to evaluate associated risks without resorting to in vivo dosimetry. The dose calculation was performed in 79 procedures through the Monte Carlo simulator PCXMC (A PC-based Monte Carlo program for calculating patient doses in medical X-ray examinations), by using the real geometrical and dosimetric irradiation conditions, automatically extracted from DICOM headers. The DAP measurements were also validated by using thermoluminescent dosimeters on an anthropomorphic phantom. The expected linear correlation between effective doses and DAP was confirmed with an R(2) of 0.974. Moreover, in order to easily calculate patient doses, conversion coefficients that relate equivalent doses to measurable quantities, such as DAP, were obtained.

Non-vascular interventional procedures: effective dose to patient and equivalent dose to abdominal organs by means of dicom images and Monte Carlo simulation / Longo, Mariaconcetta; Marchioni, C; Insero, T; Donnarumma, Raffaella; D'Adamo, Alessandro; Lucatelli, Pierleone; Fanelli, F; Salvatori, Fm; Cannavale, Alessandro; Di Castro, E. 4.. - In: RADIATION PROTECTION DOSIMETRY. - ISSN 0144-8420. - STAMPA. - 168:4(2016), pp. 509-515. [10.1093/rpd/ncv362]

Non-vascular interventional procedures: effective dose to patient and equivalent dose to abdominal organs by means of dicom images and Monte Carlo simulation

LONGO, MARIACONCETTA;DONNARUMMA, RAFFAELLA;D'ADAMO, ALESSANDRO;LUCATELLI, PIERLEONE;CANNAVALE, ALESSANDRO;
2016

Abstract

This study evaluates X-ray exposure in patient undergoing abdominal extra-vascular interventional procedures by means of Digital Imaging and COmmunications in Medicine (DICOM) image headers and Monte Carlo simulation. The main aim was to assess the effective and equivalent doses, under the hypothesis of their correlation with the dose area product (DAP) measured during each examination. This allows to collect dosimetric information about each patient and to evaluate associated risks without resorting to in vivo dosimetry. The dose calculation was performed in 79 procedures through the Monte Carlo simulator PCXMC (A PC-based Monte Carlo program for calculating patient doses in medical X-ray examinations), by using the real geometrical and dosimetric irradiation conditions, automatically extracted from DICOM headers. The DAP measurements were also validated by using thermoluminescent dosimeters on an anthropomorphic phantom. The expected linear correlation between effective doses and DAP was confirmed with an R(2) of 0.974. Moreover, in order to easily calculate patient doses, conversion coefficients that relate equivalent doses to measurable quantities, such as DAP, were obtained.
2016
Radiation protection; Monte Carlo simulation; Abdominal extra-vascular interventional procedures
01 Pubblicazione su rivista::01a Articolo in rivista
Non-vascular interventional procedures: effective dose to patient and equivalent dose to abdominal organs by means of dicom images and Monte Carlo simulation / Longo, Mariaconcetta; Marchioni, C; Insero, T; Donnarumma, Raffaella; D'Adamo, Alessandro; Lucatelli, Pierleone; Fanelli, F; Salvatori, Fm; Cannavale, Alessandro; Di Castro, E. 4.. - In: RADIATION PROTECTION DOSIMETRY. - ISSN 0144-8420. - STAMPA. - 168:4(2016), pp. 509-515. [10.1093/rpd/ncv362]
File allegati a questo prodotto
File Dimensione Formato  
Longo_Non-vascular-interventional_2016.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 293.27 kB
Formato Adobe PDF
293.27 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/848978
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact