A new selective, differential plating medium to screen the common gram-negative urinary tract pathogens is described. The medium combines adonitol fermentation, phenylalanine deaminase, and P-glucuronidase tests and allows the indole and cytochrome oxidase tests to be performed directly from the plates. High-level agreement with individual conventional tests was recorded in comparative studies with 504 cultures of gram-negative rods. There was 100% agreement, except for the Providencia spp. indole spot test (61.6% agreement). Adonitol fermentation by Providencia species could not be determined. Escherichia coli, Klebsiella pneumoniae, Proteus mirabilis, and Pseudomonas aeruginosa were identified with a high efficiency (100, 85.7, 83.5, and 100% agreement, respectively) without further testing. There was 96% overall agreement for the 267 infected urine samples tested.

NEW PLATE MEDIUM FOR SCREENING AND PRESUMPTIVE IDENTIFICATION OF GRAM-NEGATIVE URINARY-TRACT PATHOGENS / Thaller, Mc; Berlutti, Francesca; Dainelli, B; Pezzi, R.. - In: JOURNAL OF CLINICAL MICROBIOLOGY. - ISSN 0095-1137. - 26:(1988), pp. 791-793.

NEW PLATE MEDIUM FOR SCREENING AND PRESUMPTIVE IDENTIFICATION OF GRAM-NEGATIVE URINARY-TRACT PATHOGENS

BERLUTTI, Francesca;
1988

Abstract

A new selective, differential plating medium to screen the common gram-negative urinary tract pathogens is described. The medium combines adonitol fermentation, phenylalanine deaminase, and P-glucuronidase tests and allows the indole and cytochrome oxidase tests to be performed directly from the plates. High-level agreement with individual conventional tests was recorded in comparative studies with 504 cultures of gram-negative rods. There was 100% agreement, except for the Providencia spp. indole spot test (61.6% agreement). Adonitol fermentation by Providencia species could not be determined. Escherichia coli, Klebsiella pneumoniae, Proteus mirabilis, and Pseudomonas aeruginosa were identified with a high efficiency (100, 85.7, 83.5, and 100% agreement, respectively) without further testing. There was 96% overall agreement for the 267 infected urine samples tested.
1988
01 Pubblicazione su rivista::01a Articolo in rivista
NEW PLATE MEDIUM FOR SCREENING AND PRESUMPTIVE IDENTIFICATION OF GRAM-NEGATIVE URINARY-TRACT PATHOGENS / Thaller, Mc; Berlutti, Francesca; Dainelli, B; Pezzi, R.. - In: JOURNAL OF CLINICAL MICROBIOLOGY. - ISSN 0095-1137. - 26:(1988), pp. 791-793.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/80648
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 9
social impact