A fast and reliable HPLC method for the determination of 11 biogenic amines in beverages has been performed. After pre-column derivatization with dansyl-chloride a Kinetex C18 core–shell particle column (100 mm × 4.6 mm, 2.6 μm particle size) has been employed and the biogenic amines were identified and quantified in a total run time of 13 min with ultraviolet (UV) or fluorescence detection (FLD). Chromatographic conditions such as column temperature (kept at 50 °C), gradient elution and flow rate have been optimized and the method has been tested on red wine and fruit nectar. The proposed method is enhanced in terms of reduced analysis time and eluent consumption with respect of classical HPLC method as to be comparable to UHPLC methods. Green and cost-effective, this method can be used as a quality-control tool for routine quantitative analysis of biogenic amines in beverages for the average laboratory.

Fast determination of biogenic amines in beverages by a core-shell particle column / Preti, Raffaella; Antonelli, Marta Letizia; Bernacchia, Roberta; Vinci, Giuliana. - In: FOOD CHEMISTRY. - ISSN 0308-8146. - ELETTRONICO. - 187:(2015), pp. 555-562. [10.1016/j.foodchem.2014.07.080]

Fast determination of biogenic amines in beverages by a core-shell particle column

Raffaella Preti
;
Marta Letizia Antonelli;Roberta Bernacchia;Giuliana Vinci
2015

Abstract

A fast and reliable HPLC method for the determination of 11 biogenic amines in beverages has been performed. After pre-column derivatization with dansyl-chloride a Kinetex C18 core–shell particle column (100 mm × 4.6 mm, 2.6 μm particle size) has been employed and the biogenic amines were identified and quantified in a total run time of 13 min with ultraviolet (UV) or fluorescence detection (FLD). Chromatographic conditions such as column temperature (kept at 50 °C), gradient elution and flow rate have been optimized and the method has been tested on red wine and fruit nectar. The proposed method is enhanced in terms of reduced analysis time and eluent consumption with respect of classical HPLC method as to be comparable to UHPLC methods. Green and cost-effective, this method can be used as a quality-control tool for routine quantitative analysis of biogenic amines in beverages for the average laboratory.
2015
core–shell particle column; biogenic amines; dansyl chloride; wine; fruit nectar; HPLC
01 Pubblicazione su rivista::01a Articolo in rivista
Fast determination of biogenic amines in beverages by a core-shell particle column / Preti, Raffaella; Antonelli, Marta Letizia; Bernacchia, Roberta; Vinci, Giuliana. - In: FOOD CHEMISTRY. - ISSN 0308-8146. - ELETTRONICO. - 187:(2015), pp. 555-562. [10.1016/j.foodchem.2014.07.080]
File allegati a questo prodotto
File Dimensione Formato  
Preti_Fast-determination_2015.Pdf

solo gestori archivio

Note: https://doi.org/10.1016/j.foodchem.2015.04.075
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 527.46 kB
Formato Adobe PDF
527.46 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/781726
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 58
social impact