An experimental setup for complex mono-static radar cross section (RCS) measurements in the 1–10-GHzfrequency band, employing a suitably modified semianechoic chamber, is presented and characterized. The foreseen application is the measurement of the complex RCS of the human body during respiratory activity, to ease the design and optimization of ultrawideband (UWB) radar systems for breath-activity monitoring. The proposed RCS test range is calibrated by means of a readily available aluminum flat panel and its performance is tested against canonical targets, evaluating uncertainty in magnitude, and phase measurements. The setup is then employed to carry out investigations on the complex RCS of a volunteer focusing on its changes resulting from breath activity. Applying the measured RCS patterns to a specifically developed model, the feasibility of the UWB radar approach for achieving a continuous contact-less monitoring of breath activity in a subject at rest is clearly demonstrated. Finally, experimental tests of the application of the proposed radar technique to real-world scenarios are shown, and the safety of RCS measurements and UWB radar monitoring, with reference to exposure of the monitored subject to the radiated electromagnetic fields, is evaluated.

Complex radar cross section measurements of the human body for breath-activity monitoring applications / Piuzzi, Emanuele; P., D'Atanasio; Pisa, Stefano; Pittella, Erika; A., Zambotti. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 64:8(2015), pp. 2247-2258. [10.1109/TIM.2015.2390811]

Complex radar cross section measurements of the human body for breath-activity monitoring applications

PIUZZI, Emanuele;PISA, Stefano;PITTELLA, ERIKA;
2015

Abstract

An experimental setup for complex mono-static radar cross section (RCS) measurements in the 1–10-GHzfrequency band, employing a suitably modified semianechoic chamber, is presented and characterized. The foreseen application is the measurement of the complex RCS of the human body during respiratory activity, to ease the design and optimization of ultrawideband (UWB) radar systems for breath-activity monitoring. The proposed RCS test range is calibrated by means of a readily available aluminum flat panel and its performance is tested against canonical targets, evaluating uncertainty in magnitude, and phase measurements. The setup is then employed to carry out investigations on the complex RCS of a volunteer focusing on its changes resulting from breath activity. Applying the measured RCS patterns to a specifically developed model, the feasibility of the UWB radar approach for achieving a continuous contact-less monitoring of breath activity in a subject at rest is clearly demonstrated. Finally, experimental tests of the application of the proposed radar technique to real-world scenarios are shown, and the safety of RCS measurements and UWB radar monitoring, with reference to exposure of the monitored subject to the radiated electromagnetic fields, is evaluated.
2015
Anechoic chambers; biomedical monitoring; radar cross sections (RCSs); radiation safety; ultrawideband (UWB) radar
01 Pubblicazione su rivista::01a Articolo in rivista
Complex radar cross section measurements of the human body for breath-activity monitoring applications / Piuzzi, Emanuele; P., D'Atanasio; Pisa, Stefano; Pittella, Erika; A., Zambotti. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - STAMPA. - 64:8(2015), pp. 2247-2258. [10.1109/TIM.2015.2390811]
File allegati a questo prodotto
File Dimensione Formato  
Piuzzi_Complex-radar_2015.pdf

solo utenti autorizzati

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.13 MB
Formato Adobe PDF
2.13 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/763319
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 41
social impact