In order to design an accurate imaging detector for Nuclear Medicine, the energy performances of several YAP:Ce crystal arrays were investigated upon. Indeed, the new multipillar configuration used for the crystal gamma detector, needs an attentive pillars dimensions study in order to optimize the light yield, the detection efficiency and the spatial linearity. At first, the YAP:Ce matrix were coupled with a EMI 9765 traditional phototube; measurements of light yield and energy linearity were taken by irradiating the crystals with Am-241, Ba-133 and Cs-137 point-like sources. Then, the energy response and resolution of a 40 mm x 40 mm detection area YAP:Ce matrix coupled with a Hamamatsu R2486 Position Sensitive PMT were attentively analyzed. Differences were found in the energy response on the whole detection area, but with an adequate equalization procedure it is possible to recover the response homogeneity as well as improving the detector energy resolution.

Energy response and resolution of YAP : Ce matrix for imaging applications in nuclear medicine / T., Malatesta; F., Vittori; F., De Notaristefani; Pani, Roberto. - In: NUCLEAR PHYSICS. B. - ISSN 0550-3213. - STAMPA. - 61 n.3:61B(1998), pp. 658-665. (Intervento presentato al convegno 5th International Conference on Advanced Technology and Particle Physics (ICATPP-5) tenutosi a COMO, ITALY nel OCT 07-11, 1996).

Energy response and resolution of YAP : Ce matrix for imaging applications in nuclear medicine

PANI, Roberto
1998

Abstract

In order to design an accurate imaging detector for Nuclear Medicine, the energy performances of several YAP:Ce crystal arrays were investigated upon. Indeed, the new multipillar configuration used for the crystal gamma detector, needs an attentive pillars dimensions study in order to optimize the light yield, the detection efficiency and the spatial linearity. At first, the YAP:Ce matrix were coupled with a EMI 9765 traditional phototube; measurements of light yield and energy linearity were taken by irradiating the crystals with Am-241, Ba-133 and Cs-137 point-like sources. Then, the energy response and resolution of a 40 mm x 40 mm detection area YAP:Ce matrix coupled with a Hamamatsu R2486 Position Sensitive PMT were attentively analyzed. Differences were found in the energy response on the whole detection area, but with an adequate equalization procedure it is possible to recover the response homogeneity as well as improving the detector energy resolution.
1998
01 Pubblicazione su rivista::01a Articolo in rivista
Energy response and resolution of YAP : Ce matrix for imaging applications in nuclear medicine / T., Malatesta; F., Vittori; F., De Notaristefani; Pani, Roberto. - In: NUCLEAR PHYSICS. B. - ISSN 0550-3213. - STAMPA. - 61 n.3:61B(1998), pp. 658-665. (Intervento presentato al convegno 5th International Conference on Advanced Technology and Particle Physics (ICATPP-5) tenutosi a COMO, ITALY nel OCT 07-11, 1996).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/74595
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact